First Korean experience with shape-sensing robotic-assisted bronchoscopy integrated with mobile cone-beam CT: Results from the prospective ULSAN-ION study.
Ganghee Chae, Chul Park, Jin Hyoung Kim, Seung Won Ra, Kwang Won Seo, Yangjin Jegal, Hee Jeong Cha, Taehoon Lee
Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, the Republic of Korea. · Department of Pathology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, the Republic of Korea.
Key points
From the paper's conclusion- This first prospective Korean experience demonstrates that ssRAB integrated with mCBCT achieves high diagnostic yield with an acceptable safety profile for PPN diagnosis.
Abstract
INTRODUCTION: Shape-sensing robotic-assisted bronchoscopy (ssRAB) integrated with mobile cone-beam CT (mCBCT) has emerged as a promising platform for the diagnosis of peripheral pulmonary nodules (PPNs), with high diagnostic yield and low complication rates. However, no data have been reported in a Korean population. We evaluated the diagnostic yield and safety of ssRAB integrated with mCBCT in a Korean cohort. METHODS: This prospective, single-center cohort (the ULSAN-ION study) enrolled patients undergoing ssRAB with integrated mCBCT from July 2025 to April 2026 (ClinicalTrials.gov: NCT07057648). Diagnostic yield was assessed using the strict ATS/ACCP definition at the per-nodule and per-patient levels. RESULTS: A total of 111 patients with 140 PPNs were enrolled. Median age was 64.0 years (IQR, 55.5-69.5), and 51.4 % were male. Median nodule size was 14.0 mm (IQR, 10.0-19.2), and nodule morphology included solid (57.9 %), part-solid (28.6 %), and pure ground-glass opacity (13.6 %). A CT bronchus sign was absent in 70.7 % of nodules. mCBCT was performed in 88.6 % of nodules, with tool-in-lesion confirmation in 77.9 % and an overall tool-to-lesion rate of 99.1 %. Per-nodule diagnostic yield was 85.0 % (119/140) and per-patient diagnostic yield was 90.1 % (100/111). A malignant diagnosis was established in 75.7 % of patients, most commonly adenocarcinoma, and a specific benign diagnosis in 14.4 %. Pneumothorax occurred in 4.5 % of patients, with chest tube insertion required in 2.7 %. Airway bleeding (Nashville Grade ≥ 2) occurred in 1.8 %, with no Grade ≥ 3 events. CONCLUSION: This first prospective Korean experience demonstrates that ssRAB integrated with mCBCT achieves high diagnostic yield with an acceptable safety profile for PPN diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tool in lesion verification of shape-sensing robotic-assisted bronchoscopy with cone beam CT in sampling peripheral pulmonary nodulesThorax · 2025
- Diagnostic Performance and Safety Profile of Shape-sensing Robotic-assisted Bronchoscopy in Peripheral Pulmonary Lesions: A Systematic Review and Meta-Analysis.Respiration; international review of thoracic diseases · 2026
- Diagnostic Yield and Safety Profile of Shape-Sensing Robotic-Assisted Bronchoscopy in Peripheral Pulmonary Nodules 8 mm or Smaller.Lung · 2026
- Diagnostic Efficiency of Sequential Tissue Acquisition During Shape-Sensing Robotic-Assisted Bronchoscopy in a Thoracic Surgery Setting: A Biopsy-Level Analysis.Diagnostics (Basel, Switzerland) · 2026
- World Expert Consensus Recommendations on Shape-Sensing Robotic-Assisted Bronchoscopy for the Diagnosis of Peripheral Pulmonary LesionsRespiration · 2026
- Evaluating robotic-assisted bronchoscopy for bronchus-unconnected peripheral pulmonary nodules: diagnostic efficacy and safety.Journal of thoracic disease · 2026