Influence of dominant sequence artifacts on generative AI for virtual contrast-enhancement in breast MRI.
Luise Brock, Ameya Markale, Tri-Thien Nguyen, Marie Metz, Aju George, Shirin Heidarikahkesh, Hannes Schreiter, Julian Pfann Hossbach,
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054, Erlangen, Germany. Luise.Brock@uk-erlangen.de. · Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054, Erlangen, Germany.
Key points
From the paper's conclusion- We evaluated the robustness of a pix2pix-based vCE synthesis model to artifact-contaminated DWI during training and inference.
Abstract
BACKGROUND: Virtual contrast-enhanced (vCE) breast MRI is a deep learning approach for generating contrast-like images from non-contrast acquisitions. As diffusion-weighted imaging (DWI) has emerged as a major contributor to enhancement synthesis, understanding the influence of DWI-related image artifacts is important for the robustness and potential clinical implementation of AI-based contrast-free imaging approaches. We evaluated the robustness of a pix2pix-based vCE synthesis model to artifact-contaminated DWI during training and inference. MATERIALS AND METHODS: This IRB-approved, retrospective study included 1,974 multiparametric breast MRI examinations (mean age: 49 years) acquired with two clinical routine 3T MRI scanners (2017-2022). High b-value (b = 1500 s/mm2) DWI images were automatically classified for high-intensity (HI) and low-intensity (LI) artifacts using a pretrained neural network. A pix2pix 2D-GAN was trained either after excluding artifact-affected slices (vCE-clean) or using all available slices (vCE-all). Performance was evaluated using image similarity metrics, lesion-based analysis, reader assessment, and correlation of artifact scores with reconstruction errors. RESULTS: Excluding artifact-affected slices during training resulted in a small but statistically significant increase in whole-image structural similarity index (SSIM) with small effect size (vCE-all 0.843 ± 0.034; vCE-clean 0.849 ± 0.031, p < 0.001, dav = 0.20). However, lesion-based metrics and qualitative ratings of lesion enhancement and image quality were comparable between models. During Inference, strong LI DWI artifacts were associated with higher lesion-based errors. CONCLUSION: Controlling for artifacts on diffusion weighted imaging (DWI) during vCE training only minorly influenced technical metrics but not perceived image quality/lesion enhancement. In contrast, severe signal-loss artifacts during inference impaired local performance, highlighting the importance of image quality control during potential deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anguinus Sculpturae: Compositional Synthesis of Peak-Enhancement Breast DCE-MRI ScansarXiv · 2026
- Slice‐Wise Quality Assessment of High b Value Breast DWI via Deep Learning‐Based Artifact DetectionJournal of Magnetic Resonance Imaging · 2026
- MRI-to-PET synthesis in breast cancer using Pix2Pix: validation with simultaneously acquired PET/MR and lesion-level quantitative assessmentEJNMMI Physics · 2026
- Toward Contrast-Free Breast MRI: Improving Cancer Detection With Virtual Contrast Enhanced ImagingarXiv · 2026
- Mixture of Multi-Sequence Feature Difference for Contrast-Enhanced MRI SynthesisarXiv · 2026
- Evaluation of Generative Deep Learning for Synthesizing High B-Value Diffusion-Weighted MRI of Musculoskeletal TumorsRadiology Advances · 2026