Slice‐Wise Quality Assessment of High b Value Breast DWI via Deep Learning‐Based Artifact Detection
Ameya Markale, Luise Brock, Ihor Horishnyi, Dominika Skwierawska, Tri-Thien Nguyen, Dominique Hadler, Hannes Schreiter, Shirin Heidarikahkesh,
Friedrich-Alexander-Universität Erlangen-Nürnberg
Key points
From the paper's conclusion- DenseNet121 achieved AUROCs of 0.91 and 0.95 for hyper- and hypointense artifact detection, respectively, and weighted AUROCs of 0.84 and 0.90 for multiclass classification on single-slice high b value diffusion-weighted images, achieving mean scores of 3.52 ± 0.81 for hyperintense artifacts and 3.62 ± 0.65 for hypointense artifacts.
Abstract
BACKGROUND: Diffusion-weighted imaging (DWI) can support lesion detection and characterization in breast MRI. Therefore, DWI is increasingly being incorporated into breast MRI protocols to address some of the shortcomings of routine clinical breast MRI. However, especially high b value DWI can be prone to intensity artifacts that can affect diagnostic image assessment. PURPOSE: ) using deep learning, employing either a binary classification (artifact presence) or a multiclass classification (artifact intensity) approach on a slice-wise dataset. STUDY TYPE: Retrospective. STUDY POPULATION: 11,806 DWI slices were acquired from 156 examinations performed on female patients between 2022 and mid-2023. For both hyper- and hypointense artifact classification, the slices were split into test, validation, and holdout test set with 8164/1806/1836 and 8164/1820/1822 slices in these sets respectively. FIELD STRENGTH/SEQUENCE: . ASSESSMENT: Three convolutional neural network (CNN) architectures (DenseNet121, ResNet18, and SEResNet50) were trained for binary classification of hyper- and hypointense artifacts on slice-wise labeled data. The best performing model (DenseNet121) was applied to an independent holdout test set and further trained separately for multiclass classification. STATISTICAL TESTS: Performance of the networks was evaluated using accuracy, precision, recall, and areas under the receiver operating characteristic curve (AUROC) and under the precision recall curve (AUPRC). Radiologist evaluated bounding box positions on a 5-point Likert-like scale across 150 slices for validation and 200 slices for the holdout test set, derived from the network's Grad-CAM heatmaps. RESULTS: DenseNet121 achieved AUROCs of 0.91 and 0.95 for hyper- and hypointense artifact detection, respectively, and weighted AUROCs of 0.84 and 0.90 for multiclass classification on single-slice high b value diffusion-weighted images, achieving mean scores of 3.52 ± 0.81 for hyperintense artifacts and 3.62 ± 0.65 for hypointense artifacts. DATA CONCLUSION: ) using CNNs, particularly DenseNet121, suggests potential reliability and requires further validation. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 3.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of dominant sequence artifacts on generative AI for virtual contrast-enhancement in breast MRI.BMC medical imaging · 2026
- Evaluation of Generative Deep Learning for Synthesizing High B-Value Diffusion-Weighted MRI of Musculoskeletal TumorsRadiology Advances · 2026
- The role of diffusion-weighted imaging in breast cancer: from diagnosis to treatment monitoring and follow-up.Diagnostic and interventional radiology (Ankara, Turkey) · 2026
- Deep learning-based reconstruction for multi-shot breast DWI: Quantitative and qualitative improvements.European journal of radiology · 2026
- Impact of DWI quality and tumor complexity on deep learning-based segmentation of rectal cancer using multicenter MRI dataEuropean Radiology Abdomen · 2026
- Image Quality Assessment of Diffusion-Weighted Imaging (DWI) and Its Impact on Apparent Diffusion Coefficient (ADC) as a Quantitative Imaging Biomarker for Predicting Response to Neoadjuvant Chemotherapy in High-Risk Early Breast CancerTomography · 2026