Automatic measurement of knee parameters in three-dimensional computed tomography models: a deep learning-based approach.
Lingce Kong, Jingyi Liu, Huijun Kang, Wei Lin, Hong Song, Fei Wang
Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, 050051, China. · School of Computer Science and Technology, Beijing Institute of Technology, Beijing, 100081, China.
Key points
From the paper's conclusion- The GU2-Net-based automated measurement system achieved high accuracy, comparable to manual measurements, demonstrating its potential for clinical application.
Abstract
BACKGROUND: This study evaluates a deep learning algorithm for automated measurement of knee parameters from three-dimensional (3D) computed tomography (CT) reconstructions. METHODS: We analyzed 323 CT scans from patients with normal knee morphology (mean age 39.10 ± 11.34 years; 200 male), randomly split into a model development dataset (Dataset 1) and a hold-out test set (Dataset 2). Initial 3D reconstructions of the femur, distal femoral epiphyseal line, tibia, and proximal tibial epiphyseal line were generated using Materialise Mimics software, followed by manual annotation of 24 anatomical landmarks. A 3D convolutional neural network (CNN) based on the GU2-Net architecture was trained on Dataset 1 to predict landmark probability maps, from which 22 knee joint morphological parameters were calculated. Model performance was assessed on two datasets using intraclass correlation coefficients (ICC), mean absolute differences (MAD), root mean square (RMS) values, paired t-tests, Benjamini-Hochberg false discovery rate (FDR) correction for multiple testing, and two one-sided tests (TOST) for clinical equivalence verification. RESULTS: The mean absolute difference between predicted and manually annotated landmarks was 1.95 mm in Dataset 1 and 2.04 mm in Dataset 2. The percentage of correct keypoints (PCK) at a 4 mm threshold was 95.83% in Dataset 1 and 94.34% in Dataset 2. Automated measurements showed strong agreement with manual results (ICC = 0.880-0.993, MAD = 0.39-1.46, RMS = 0.46-1.97), with no statistically significant differences after FDR correction (all adjusted p > 0.05). TOST with clinical margins (± 2.0 mm for linear parameters, ± 1.0° for angular parameters) confirmed clinical equivalence for most parameters, with only 5 parameters failing to reach equivalence due to strict margins. CONCLUSION: The GU2-Net-based automated measurement system achieved high accuracy, comparable to manual measurements, demonstrating its potential for clinical application. TRIAL REGISTRATION: Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- nnU-NET BASED 3D SEGMENTATION OF HIGH-RESOLUTION KNEE CT SCANS FOR THE ANALYSIS OF SHAPE AND INTRA-ARTICULAR CALCIFICIATIONS.Osteoarthritis imaging · 2026
- Measuring Knee Alignment Following Distal Femur Fracture Surgery: A Novel Deep Learning Approach.Journal of orthopaedic trauma · 2026
- AUTOMATIC FEMOROTIBIAL JOINT SPACE PATCH SELECTION FROM WEIGHT-BEARING CONE-BEAM COMPUTED TOMOGRAPHY BONE SEGMENTATIONS.Osteoarthritis imaging · 2026
- Longitudinal 3D quantification of joint space from CT images: Semi-automatic segmentation and feasibility of nnU-Net automation.Osteoarthritis imaging · 2026
- Development and validation of a deep learning-based automated Notch Width Index measurement system from anteroposterior knee radiographs.The Knee · 2026
- 3D QUANTITATIVE MEASUREMENTS OF JOINT SPACING BASED ON SEMI-AUTOMATIC AND AUTOMATIC SEGMENTATION, CONDUCTED 36 MONTHS APART, USING COMPUTED TOMOGRAPHY IMAGES.Osteoarthritis imaging · 2026