Deep learning model for automatic detection of incidental adrenal abnormalities on low-dose computed tomography images.
Kexin Wang, He Wang, Shiwei Chen, Wencong Han, Wenzhi Gao, Guangyong Shi, Tong Liu, Chongchen Ma,
Department of Radiology, Peking University First Hospital, Beijing, 100034, China. · Department of Urology, Peking University First Hospital; Institution of Urology, Peking University; Beijing Key Laboratory of Urogenital Diseases (Male) Molecular Diagnosis and Treatment Center; National Urological Cancer Center, Beijing, 100034, China.
Key points
From the paper's conclusion- The deep learning models showed promise in automated adrenal segmentation and classification, highlighting AI's potential to improve detection of adrenal abnormalities in LDCT scans.
Abstract
BACKGROUND: To investigate the feasibility of employing deep learning models for automated segmentation and classification of adrenal incidental abnormalities on low-dose CT images. METHODS: Four distinct CT cohorts were retrospectively collected for deep learning models development (cohort A, n = 2574; cohort B, n = 1205), internal evaluation (cohort C, n = 3681), and external evaluation (cohort D, n = 779). Two experienced uroradiologists independently reviewed the CT images and labeled the adrenal glands as normal or abnormal based on predefined criteria encompassing both density and morphological abnormalities, with any discrepancies resolved through consultation. The model development cohorts were divided into a training set, a validation set, and a test set. Deep learning models for segmentation and classification were trained and evaluated on internal and external sets, with the dice similarity coefficient (DSC), area under precision-recall curves (AUPRC), and area under receiver operating characteristic curves (AUROC) as evaluation metrics. Adrenal descriptions from radiology reports were extracted to compare with the model's performance. RESULTS: For adrenal gland segmentation, the DSC values for the test set, internal validation cohort, and external validation cohort were 0.839 (IQR: 0.783-0.871), 0.870 (IQR: 0.819-0.902), and 0.799 (IQR: 0.729-0.849), respectively. For adrenal gland classification, the AI model achieved AUPRC values of 0.913, 0.753, and 0.927 in the test set, internal validation cohort, and external validation cohort, respectively, outperforming routine radiology reporting (AUPRC: 0.809, 0.708, 0.591; all P < 0.05). Corresponding AUROC values were 0.956, 0.942, and 0.977 for the AI model, which also outperformed routine radiology reporting (AUROC: 0.889, 0.705, 0.551; all P < 0.05). CONCLUSIONS: The deep learning models showed promise in automated adrenal segmentation and classification, highlighting AI's potential to improve detection of adrenal abnormalities in LDCT scans. TRIAL REGISTRATION: This study has been registered on ClinicalTrials.gov on August 25, 2025, with the unique identifier NCT07198152.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- xsCT-based radiomics for adrenal incidentaloma characterization.La Radiologia medica · 2026
- Diagnostic Accuracy of Deep Learning for Detection of Incipient and Advanced Radiographic Interproximal Caries in Mixed Dentition Periapical Radiographs.Journal of dentistry · 2026
- Accuracy of deep learning in quantifying epicardial adipose tissue: a systematic review and meta-analysis.Internal and emergency medicine · 2026
- Development and Multicenter Validation of a Hybrid Radiomics-Deep Learning Model for Risk Stratification of O-RADS 4 Adnexal Masses.Academic radiology · 2026
- Uncertainty quantification for detecting out-of-distribution cases in deep learning segmentation of head and neck organs of interest.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Deep Learning for the Assessment of Alveolar Bone Loss on Intraoral Radiographs: A Systematic Review.Diagnostics (Basel, Switzerland) · 2026