Low-kV high-pitch one-scan aortic and coronary CT angiography using dual-source photon-counting CT: comparison with separate acquisition strategies.
Hiroaki Kato, Suguru Araki, Satoshi Nakamura, Takafumi Ouchi, Akio Yamazaki, Takatoshi Higashigawa, Noriyuki Kato, Yasutaka Ichikawa,
Department of Radiology, Mie University Hospital, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan. · Department of Advanced Diagnostic Imaging, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan. s-nakamura@med.mie-u.ac.jp.
Key points
From the paper's conclusion- This study aimed to compare a low-kV one-scan CCTA/CTAO protocol with a low-kV dedicated CCTA followed by a higher-kV CTAO acquisition (separate-scan) regarding radiation dose and image quality.
Abstract
BACKGROUND: For patients with aortic diseases, coronary CT angiography (CCTA) is performed for preoperative evaluation of coronary artery disease, often in combination with CT angiography of thoracic and abdominal aorta (CTAO) within the same examination. A dual-source photon-counting detector CT (PCD-CT) offers advantages including improved dose efficiency and reduction of electronic noise, which might help maintain image quality even at low tube voltages. This study aimed to compare a low-kV one-scan CCTA/CTAO protocol with a low-kV dedicated CCTA followed by a higher-kV CTAO acquisition (separate-scan) regarding radiation dose and image quality. METHODS: This retrospective, single-center study included 42 patients who underwent CCTA and CTAO using PCD-CT for preoperative CAD screening for aortic disease: 19 had separate-scan, 23 had one-scan CCTA and CTAO. Image quality for CCTA was assessed using a four-point scale (excellent, good, fair, non-diagnostic). Image quality for CTAO was assessed using a five-point scale (excellent, good, moderate, poor, non-diagnostic). RESULTS: Radiation dose was significantly lower in the one-scan group compared to the separate-scan group (mean total dose-length product, 175.8 ± 71.1 vs. 769.4 ± 212.1 mGy·cm; P < 0.001). For CCTA, subjective image quality scores were comparable between the two groups (P = 0.537), although the separate-scan group showed significantly higher objective CNR compared to the one-scan group (P =0.025). For CTAO, the subjective image quality was significantly superior in the one-scan group (P < 0.01), despite comparable CNR between the groups (P = 0.13). The proportions of good or excellent ratings were 97.1% and 98.4% for CCTA, and 85.1% and 91.3% for CTAO in the separate-scan and one-scan groups, respectively. CONCLUSIONS: The low-kV one-scan strategy using PCD-CT substantially reduced radiation dose while maintaining comparable subjective CCTA quality and superior subjective CTAO quality. This approach may provide a dose-efficient option in selected patients requiring primary aortic assessment with concomitant coronary screening; however, its adequacy for preoperative CAD screening remains to be established.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- First clinical experience with the NAEOTOM Alpha.Peak photon-counting CT: high diagnostic reliability and ultra-low-dose CCTA in routine practiceEuropean Heart Journal · 2026
- Diagnostic Performance of Photon‐Counting Coronary CT Angiography in Patients Undergoing TAVI: A Comparison With Invasive AngiographyEuropean Journal of Clinical Investigation · 2026
- Single-Bolus Sequential Triple-Rule-Out CT Angiography: Image Quality and Radiation Dose on Wide-Area Detector and Dual-Source CT.Journal of clinical medicine · 2026
- Photon-Counting CT Enables Higher Image Quality at a Lower Radiation Dose Compared with a 256-Slice Energy-Integrating Detector CT in Pediatric Patients with Congenital Heart DiseaseDiagnostics · 2026
- Radiation and Contrast Medium Dosage Optimization of Coronary CT Angiography While Combining Personalized Patient Protocol Technology and Automated Tube Voltage Selection Technology.Diagnostics (Basel, Switzerland) · 2026
- Photon-counting computed tomography: a revolution in cardiac imagingEuropean Heart Journal · 2025