Diagnostic Performance of Photon‐Counting Coronary CT Angiography in Patients Undergoing TAVI: A Comparison With Invasive Angiography
Tara Zuhair Kassem, Maximilian Moshage, Shaun Khanna, Silvia Smolka, Monique Tröbs, Johannes Michael Altstidl, Venera Bytyqi, Damini Dey,
Key points
From the paper's conclusion- PCCT coronary angiography may serve as a non‐invasive gatekeeper to invasive coronary angiography and support a more efficient pre‐procedural workflow.
Abstract
Background Since coronary artery disease (CAD) is common in patients undergoing transcatheter aortic valve implantation (TAVI), invasive coronary angiography (ICA) is performed in preparation for the procedure, although many patients do not require coronary intervention. Photon‐counting Computed Tomography (PCCT) offers improved spatial resolution compared with conventional energy‐integrating detector CT. The aim of this study was to evaluate the diagnostic performance of PCCT for the detection of significant CAD in patients undergoing TAVI evaluation using ICA as the reference standard. Methods In this single‐center study, 201 consecutive patients undergoing preprocedural TAVI work‐up with both PCCT and ICA were included. Sensitivity, specificity, and positive and negative predictive values (PPV and NPV) were calculated at ≥ 50% and ≥ 70% stenosis thresholds using recorded binary classifications. Non‐evaluable coronary territories were considered CT‐positive. Patient‐level 95% confidence intervals (CIs) were exact binomial; vessel‐level CIs used patient‐cluster bootstrap resampling. Results Of 201 patients were included (mean age 79.6 ± 7.2 years; 118 [58.7%] male). Image quality was excellent or good in 167 patients (83.1%). On ICA, ≥ 50% stenoses were present in 126 patients (62.7%) and ≥ 70% stenoses in 114 (56.7%). For ≥ 50% stenosis, per‐patient sensitivity, specificity, PPV, and NPV were 98.4% (95% CI, 94.4%–99.8%), 93.3% (85.1%–97.8%), 96.1% (91.2%–98.7%), and 97.2% (90.3%–99.7%), respectively. Corresponding values for ≥ 70% stenosis were 99.1% (95.2%–100.0%), 89.7% (81.3%–95.2%), 92.6% (86.5%–96.6%), and 98.7% (93.1%–100.0%). At the ≥ 50% threshold, 72 patients (35.8%) were CT‐negative; 70 were true negatives and two were false negatives. Conclusions PCCT demonstrates high diagnostic accuracy for the detection and exclusion of significant CAD in patients undergoing TAVI evaluation. PCCT coronary angiography may serve as a non‐invasive gatekeeper to invasive coronary angiography and support a more efficient pre‐procedural workflow.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultra-high resolution photon-counting detector coronary CT angiography: diagnostic accuracy in patients with high Agatston scoresEuropean Radiology · 2025
- Comparative analysis of photon-counting and energy-integrating detector CT to identify obstructive coronary artery diseaseEuropean Radiology · 2025
- Diagnostic accuracy of photon-counting detector CT for detection of coronary in-stent restenosis.Cardiovascular revascularization medicine : including molecular interventions · 2026
- In vivo coronary stent evaluation using photon-counting computed tomography: diagnostic performance.European radiology · 2026
- Standard and Ultrahigh Resolution Photon-Counting Coronary CTA–Derived FFR Against Invasive FFR AssessmentJACC. Cardiovascular imaging · 2026
- Value of coronary CT Angiography in ruling-out coronary ar-tery disease in elderly patients candidates to TAVIEuropean Heart Journal · 2026