BMC gastroenterology

A structured ultrasound approach for quantifying segmental terminal ileum motility: the terminal ileum motility index.

Abdullah Enes Berksoy, Mehmet Cihan Karacaoğlu

Department of Radiology, Göksun State Hospital, Kahramanmaraş, Turkey. enesberksoy513@gmail.com. · Department of Radiology, Ankara Etlik City Hospital, Ankara, Turkey.

Observational

Key points

From the paper's conclusion
  • Structured cine ultrasonography enabled quantification of terminal ileal contractile activity and provided initial distributions in fasting healthy adults. TIMI integrated contraction frequency and deformation magnitude while preserving good same-recording inter-reader agreement. Although predominantly count-driven in this cohort, TIMI retained amplitude information and should be reported alongside its components. These findings establish a quantitative framework for multi-operator, test-retest, stimulus-response, independent-validation, and patient-cohort studies.

Abstract

BACKGROUND: Quantifying small-bowel motility remains challenging. We developed a structured cine-ultrasound protocol and introduced the Terminal Ileum Motility Index (TIMI), combining contraction frequency with fractional cross-sectional area reduction. METHODS: In this prospective cross-sectional study, one operator examined 205 healthy adults after a 6-8-h fast. The terminal ileum was observed in a stable transverse plane for up to 20 min. After the first definite contraction, a 3-min active window was divided into three 1-min segments. Minute-specific TIMI equaled count multiplied by mean fractional amplitude from up to the first three contractions; final TIMI was their three-minute mean. In the full-cohort sensitivity analysis, participants without detected contractions had count and TIMI coded as zero and amplitude unestimated. Thirty-five randomly selected contraction-positive recordings were independently re-measured by both readers using the same predefined quantitative protocol, with each reader blinded to the other reader's measurements. Two months later, each reader performed blinded exploratory 0-3 visual grading of these recordings plus 15 no-contraction recordings. RESULTS: The terminal ileum was technically evaluable in 182/205 participants (88.8%), and contractions were detected in 128/182 (70.3%). In the active-window cohort, mean amplitude, 3-min count, and TIMI were 54.55 ± 8.51%, 11.80 ± 4.40, and 2.10 ± 0.99. Full-cohort mean count and TIMI were 8.30 ± 6.54 and 1.48 ± 1.27. Count and amplitude were modestly correlated (ρ = 0.359), whereas TIMI correlated with count and amplitude (ρ = 0.945 and 0.603; all p < 0.001). Same-recording ICCs for amplitude, count, and TIMI were 0.837, 0.783, and 0.837. Inter-reader biases were small; count and TIMI showed proportional bias, with TIMI limits of agreement of - 0.929 to 0.947. Visual grading showed substantial ordinal agreement (linearly weighted κ = 0.718), and visual-score correlations with TIMI and count did not differ significantly. CONCLUSIONS: Structured cine ultrasonography enabled quantification of terminal ileal contractile activity and provided initial distributions in fasting healthy adults. TIMI integrated contraction frequency and deformation magnitude while preserving good same-recording inter-reader agreement. Although predominantly count-driven in this cohort, TIMI retained amplitude information and should be reported alongside its components. These findings establish a quantitative framework for multi-operator, test-retest, stimulus-response, independent-validation, and patient-cohort studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A structured ultrasound approach for quantifying segmental terminal ileum motility: the terminal ileum motility index — Science Skim