Diagnostics

Ultrasound Activity Scores in Ulcerative Colitis: Comparison Between the International Bowel Ultrasound Segmental Activity Score (IBUS-SAS) and Milan Ultrasound Criteria (MUC)

Irene Mignini, Giorgio Esposto, Federica Di Vincenzo, Rossella Maresca, Simone Parello, Fabio Cascella, Angelo Del Gaudio, Linda Galasso,

Observational · n=87

Key points

From the paper's conclusion
  • The Milan Ultrasound Criteria (MUC) and the International Bowel Ultrasound Segmental Activity Score (IBUS-SAS) are promising tools, but their comparative performance remains unclear.

Abstract

Background and Aims: As intestinal ultrasound (IUS) is increasingly used to monitor ulcerative colitis (UC), standardized activity scores are recommended. The Milan Ultrasound Criteria (MUC) and the International Bowel Ultrasound Segmental Activity Score (IBUS-SAS) are promising tools, but their comparative performance remains unclear. This study aimed to compare their diagnostic accuracy and define optimal cut-off values for detecting active disease. Methods: In this prospective study, adults with left-sided or extensive ulcerative colitis (UC) undergoing intestinal ultrasound (IUS) were evaluated. Disease activity was assessed clinically (Patient-Reported Outcome 2, PRO-2), biochemically (C-reactive protein, CRP; fecal calprotectin FC), and endoscopically (Mayo endoscopic subscore, MES). Correlations were analyzed with Spearman’s coefficient, and diagnostic accuracy with receiver operating characteristic (ROC) curve analysis to define optimal cut-offs. Results: A total of 87 patients underwent 297 IUS examinations. IBUS-SAS and MUC were strongly correlated (ρ = 0.82; p < 0.01) and significantly associated with clinical, endoscopic, and biochemical disease activity. Correlations with PRO-2 and MES were moderate, while weaker associations were observed with inflammatory biomarkers. ROC curves showed comparable accuracy for detecting clinical and endoscopic activity (AUC 0.758–0.790). Optimal cut-offs for active disease (MES ≥ 2) were MUC ≥ 7.88 and IBUS-SAS ≥ 25.0. Cut-offs for severe disease (MES = 3) were also identified (MUC ≥ 8.40 and IBUS-SAS ≥ 49.2). MUC had a higher AUC for detecting biochemical activity based on FC (AUC 0.730 vs. 0.652; p = 0.015). Conclusions: MUC and IBUS-SAS were strongly correlated and showed similar diagnostic performance in UC, with MUC possibly reflecting biochemical activity better, suggesting a possible role of the two scores in IUS monitoring.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers