Anesthetic management for pulsed field ablation in a patient with Eisenmenger syndrome using general anesthesia with spontaneous ventilation: a case report
Jie Ding, Beibei Wang, Fuxia Yan, Su Yuan, Yuan Jia
Key points
From the paper's conclusion- An anesthesia strategy utilizing general anesthesia with a laryngeal mask airway and spontaneous ventilation avoids the deleterious effects of positive intrathoracic pressure on right ventricular preload, allowing the PFA procedure to be completed with stable physiology and acute rhythm control.
Abstract
Background Drug-refractory atrial tachyarrhythmia is an important precipitating factor for recurrent heart failure decompensation in patients with Eisenmenger syndrome (ES). Although percutaneous pulsed field ablation (PFA) represents a potential therapeutic option for arrhythmia management, its application in this population is challenging due to the substantial anesthetic risks associated with severe pulmonary hypertension, right ventricular dysfunction, and profound hypoxemia. Case presentation We report the case of a 48-year-old male with ES and chronic heart failure who presented with recurrent, drug-refractory atrial flutter/fibrillation. Given concerns regarding hemodynamic deterioration during positive pressure ventilation, general anesthesia with spontaneous ventilation supported by a laryngeal mask airway was selected. The PFA was successfully completed without intraoperative hemodynamic instability. The patient was transferred to the ward with supplemental oxygen support. However, despite successful arrhythmia ablation and favorable intraprocedural physiology, he developed progressive heart failure and multiorgan dysfunction and died 20 days after the procedure. Conclusion The safe implementation of PFA relies on absolute immobility and stable hemodynamics. An anesthesia strategy utilizing general anesthesia with a laryngeal mask airway and spontaneous ventilation avoids the deleterious effects of positive intrathoracic pressure on right ventricular preload, allowing the PFA procedure to be completed with stable physiology and acute rhythm control.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrical storm after pulsed field ablation of atrial fibrillation in patients with impaired left ventricular functionHeart Rhythm · 2026
- A Case Report of Right Phrenic Nerve Palsy Following Pulsed Field Ablation in a Patient with Persistent Atrial Fibrillation.The Journal of innovations in cardiac rhythm management · 2026
- Pulsed-Field Ablation for Atrial Fibrillation in Partial Anomalous Pulmonary Venous Return With Right Atrial Drainage of Both Right Pulmonary Veins.Journal of arrhythmia · 2026
- Sedation and anaesthesia in pulsed-field ablation for atrial fibrillation: mechanisms, procedural requirements, and real-world practice.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Pulsed field ablation versus conventional thermal ablation for atrial fibrillation: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Esophageal safety of pulsed field versus radiofrequency ablation including posterior wall isolation in persistent atrial fibrillation: a blinded endoscopic studyEuropean Heart Journal · 2026