Modified nasopharyngeal airway device facilitates nasal fiberoptic intubation for trainee anesthesiologists: a randomized clinical study.
Amorn Vijitpavan, Poonyanuch Charoenkoop, Waralak Raksong, Rachapha Kitphasert
Department of Anesthesiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, 10400, Thailand. · Department of Anesthesiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, 10400, Thailand. poonyanuch.sri@mahidol.ac.th.
Key points
From the paper's conclusion- The mNPA significantly improved nasotracheal intubation time and success rates and reduced the number of attempts and bleeding complication rates for operators with limited experience in performing nasal fiberoptic intubation in non-difficult airway patients.
Abstract
BACKGROUND: Fiberoptic nasotracheal intubation is an essential skill for anesthesiologists. Trainee anesthesiologists often face challenges due to the complex anatomy of the nasopharynx and the risk of upper airway collapse after anesthesia administration, which can lead to confusion and difficulty in identifying the glottic opening. This study evaluated whether a modified nasopharyngeal airway (mNPA) device can assist less experienced operators in performing nasal fiberoptic intubation on anesthetized patients with non-difficult airway. METHODS: This randomized controlled trial analyzed 54 patients undergoing elective surgery with nasal intubation. The patients were then assigned to either the mNPA group (n = 28) or the conventional nasal fiberoptic intubation (cNFI) group (n = 26). In the mNPA group, a modified airway guided the flexible fiberoptic bronchoscope to the glottis, and the device was subsequently removed to facilitate intubation. Trainee anesthesiologists performed all intubations. The primary outcome was intubation time. The secondary outcomes included first-attempt success rate and bleeding complications. RESULTS: The mNPA group had a significantly faster vocal cord visualization time (11.49 vs. 47.56 s, P < 0.001) and a shorter intubation time (56.25 vs. 107.02 s, P < 0.001) than the cNFI group. The mNPA group had a significantly higher first-attempt success rate (96.43% vs. 73.08%, P value = 0.038) and a significantly lower incidence of blood staining in the periglottic area (3.57% vs. 26.92%, P value = 0.022) than the cNFI group. CONCLUSION: The mNPA significantly improved nasotracheal intubation time and success rates and reduced the number of attempts and bleeding complication rates for operators with limited experience in performing nasal fiberoptic intubation in non-difficult airway patients. TRIAL REGISTRATION: Thai Clinical Trials Registry TCTR20230809006. Registered 9 August 2023.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of the modified flexible lightwand versus flexible bronchoscope for nasotracheal intubation: a protocol for a randomised controlled trial.BMJ open · 2026
- Conventional versus nasopharyngeal airway-guided bougie technique for nasotracheal intubation in adult patients: A randomised controlled studyIndian Journal of Anaesthesia · 2026
- Distance Hands‐On Training Versus Video Instruction for Flexible Laryngeal Mask Airway Management: A Protocol for a Multicenter Randomized Controlled TrialActa Anaesthesiologica Scandinavica · 2026
- The C-MAC video laryngoscope versus fiberoptic bronchoscope for awake intubation under ketofol sedation in cervical spine injury patients who are immobilized with a cervical collar: a prospective randomized controlled trial.Journal of trauma and injury · 2026
- Technical Assessment of Simulated Neonatal Intubation Using Multi-Angle Video.American journal of perinatology · 2026
- Universal videolaryngoscopy and intubation outcomes in anaesthesia trainees: A subanalysis of the multicentre VIDEOLAR-SURGERY trial.Anaesthesia and intensive care · 2026