科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ American journal of perinatology2026-08-19

Technical Assessment of Simulated Neonatal Intubation Using Multi-Angle Video.

Hannah Gu, Rodrigo B Galindo, Matthew Cranshaw, Tami Alade, Janene H Fuerch, Nicole K Yamada, Katie Hunt, Lisa Marie Pineda, Paula McWilliam, Nancy Kent, Louis Halamek

一句话结论 · In one sentence

Objective technique differences may inform targeted training strategies and competency assessment in neonatal airway management.

原始摘要(英文原文)· Original abstract
BACKGROUND: Neonatal intubation is a critical skill, yet trainees may not achieve procedural competency before program completion. This study quantified technical differences between novice and expert intubators using multi-angle and intraoral video during simulated neonatal intubation. METHODS: Participants from a level IV NICU-including MDs, NNPs, RNTS's, and residents-completed three intubations each on preterm and term manikins. Experts were defined as those with >10 successful intubations and >1 year of NICU experience. Outcomes included failure rate, time metrics, glottic view, and laryngoscope hold. RESULTS: Thirty-eight subjects participated (18 novices, 20 experts). Intubation failure did not differ significantly, but experts completed term manikin intubations faster (12.5s vs. 15.8s, p<0.001), visualized cords sooner in preterm trials, and advanced the ETT faster in term trials. Glottic views were similar, though laryngoscope hold technique differed significantly (p=0.006). CONCLUSION: Objective technique differences may inform targeted training strategies and competency assessment in neonatal airway management.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Technical Assessment of Simulated Neonatal Intubation Using Multi-Angle Video. — 科研速览 Science Skim