Do modular tapered long stems differ in stability and function? A prospective comparison of two stems in complex femoral revision THA
M. H. Fahmy, Mostafa Ahmed Shawky
Cairo University
Key points
From the paper's conclusion- These findings support the use of modular tapered fluted stems as reliable solutions in complex femoral rTHA.
Abstract
BACKGROUND: )-have limited direct comparative evidence. This study aimed to prospectively compare radiographic stem subsidence (primary outcome), as well as functional outcomes, complications, survivorship, and secondary outcomes, between Type A and Type B modular long stems in femoral rTHA. METHODS: In this single-center randomized prospective study, 110 patients undergoing femoral revision rTHA were randomly assigned to receive either Type A (n = 55) or Type B (n = 55) stems. All procedures were performed by experienced revision surgeons under standardized perioperative and rehabilitation protocols. Radiographs were analyzed for stem subsidence, osseointegration, and limb-length restoration. Functional outcomes were assessed using the Harris Hip Score (HHS), Oxford Hip Score (OHS), and European Quality of Life Visual Analogue Scale (EQ-VAS) at baseline and final follow-up (mean 61.4 months). Complications and stem survivorship were recorded prospectively. Statistical analysis included paired and unpaired comparisons, correlation, regression, and Kaplan-Meier survival estimates. RESULTS: Baseline demographics and femoral defect severity were comparable. Both groups achieved high radiological stability, with mean distal subsidence of 1.3 ± 0.7 mm (Type A) and 1.5 ± 0.9 mm (Type B; p = 0.24), and osseointegration in > 92% of cases. Limb-length and offset restoration were similar. HHS improved significantly in both groups (Type A: 44.7 → 88.1; Type B: 45.1 → 87.3; p < 0.001), with > 80% achieving good-to-excellent outcomes. Complication rates were low and comparable. Five-year stem survivorship was 98.2% (Type A) and 97.6% (Type B). Early full weight-bearing and lower Paprosky defect grades independently predicted superior functional outcomes, whereas stem type did not. CONCLUSIONS: Both Type A and Type B modular tapered fluted stems demonstrated durable fixation, minimal subsidence, low complication rates, and excellent mid-term functional recovery. Radiographic stem subsidence did not differ between groups, indicating that design variations do not significantly affect clinical outcomes. These findings support the use of modular tapered fluted stems as reliable solutions in complex femoral rTHA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Outcomes with use of a modular, cementless, tapered and fluted femoral prosthesis in revision hip arthroplasty with mid-term follow-up.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- Outcomes of revision from hip resurfacing to total hip arthroplasty: a matched comparative study with primary total hip arthroplasty at seven and a half years follow-up.International orthopaedics · 2026
- Similar 2 year migration patterns for a shortened and a distally reduced stem design in uncemented total hip arthroplasty: a randomized controlled trial using radiostereometric analysis.Acta orthopaedica · 2026
- Ten-year migration analysis of a cementless metaphyseal-anchored short femoral stem in total hip arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Stem Type as an Independent Correlate of Functional Outcome Following Total Hip Arthroplasty: A Comparative Study of Short-Stem and Standard-Stem Femoral Implants.Journal of functional biomaterials · 2026
- A randomized study on migration of the Spectron EF and the Charnley flanged 40 cemented femoral stems: secondary analysis of a randomized controlled trial using radiostereometric analysis (RSA) with 10 years' follow-up.Acta orthopaedica · 2026