Intraocular Thermodynamics During Vitreoretinal Surgery.
Geovanni Jassiel Ríos-Nequis, Julio Enrique Covarrubias-Avilés, Arthur Levine-Berebichez, Ana Cristina Esquivel-Muciño, Juan Abel Ramírez-Estudillo
Retina and Vitreous Department, Fundación Hospital Nuestra Señora de la Luz, Mexico City, Mexico.
Key points
From the paper's conclusion- Intraocular temperature varies dynamically during vitreoretinal surgery and is not uniformly distributed within the vitreous cavity. Intraoperative cooling and spatial temperature gradients suggest that intraocular thermodynamics may influence retinal physiology, fluidics behavior, and tamponade properties. These findings underscore the role of intraocular thermodynamics as a clinically relevant factor in vitreoretinal surgery.
Abstract
PURPOSE: To characterize intraocular temperature changes before, during, and after vitreoretinal surgery at predefined anatomic locations within the vitreous cavity. METHODS: This prospective, observational, longitudinal study included patients undergoing vitreoretinal surgery. Intraocular temperature was measured using a 29-gauge/3-cm MT needle connected to a BAT-12R Physitemp thermometer at standardized anatomic sites (anterior, middle, and posterior vitreous) and predefined surgical stages, including pre-, intra-, and post-vitrectomy, as well as before and after phacoemulsification. RESULTS: Twenty eyes were included. At the start of surgery, mean anterior chamber and vitreous cavity temperatures were 28.69°C and 32.16°C, respectively. After phacoemulsification, vitreous temperature decreased by 3.01°C. During vitrectomy, intraocular temperature decreased across all measured regions compared with baseline pre-vitrectomy values (-1.5°C anterior, -2.2°C middle, and -1.8°C posterior vitreous). A posterior-to-anterior temperature gradient was observed, with higher baseline temperatures in the posterior vitreous. CONCLUSIONS: Intraocular temperature varies dynamically during vitreoretinal surgery and is not uniformly distributed within the vitreous cavity. Intraoperative cooling and spatial temperature gradients suggest that intraocular thermodynamics may influence retinal physiology, fluidics behavior, and tamponade properties. These findings underscore the role of intraocular thermodynamics as a clinically relevant factor in vitreoretinal surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of Ultrasound Modality, Viscosurgical Devices, and Automated Energy Modulation on Intraocular Thermal Exposure During Phacoemulsification.Journal of cataract and refractive surgery · 2026
- Effect of temperature variation on the corneal endothelial cell during femtosecond laser-assisted cataract surgery compared with conventional phacoemulsification cataract surgery: A prospective studyMedicine · 2026
- Low Versus High Intraoperative Intraocular Pressure During Phacoemulsification Cataract Surgery: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.Journal of clinical medicine · 2026
- Imaging Approaches to Quantifying the Biomechanical Properties of the Human Vitreous In Vivo: A Review.Bioengineering (Basel, Switzerland) · 2026
- Steady-state thermal homeostasis model of heat generated and dissipated in the human retina.Physical biology · 2026
- Influence of Room Illumination on Corneal Densitometry.Translational vision science & technology · 2026