Image quality of combined PROPELLER and deep learning reconstruction using an accelerated T2-weighted imaging technique for prostate MRI.
Rory L Cochran, Ranjodh S Dhami, William R Bradley, Robert G Rasmussen, Madhangi Parameswaran, Eugene Milshteyn, Ajeetkumar Gaddipati, Mary Thomas,
Department of Radiology, Massachusetts General Hospital, Mass General Brigham, Boston, MA, USA. · GE HealthCare, Boston, MA, USA.
Key points
From the paper's conclusion- VORTEX with PR and DLR can achieve fast high-quality T2w sagittal and coronal imaging of prostate, with all acquisitions completed within 95 s per imaging plane and a total triplanar acquisition time of 4 min 7 s.
Abstract
BACKGROUND: Motion artifacts can degrade prostate MRI quality. PROPELLER read-out (PR), a radial acquisition technique, is an established approach that can reduce motion artifacts but requires longer acquisition times. We explored whether combining PR with accelerated acquisition and reconstruction methods yields image quality gains while reducing scan times. PURPOSE: To compare the image quality of standard Cartesian (CR) and PROPELLER read-outs (PR) using an accelerated fast spin echo-based technique (VORTEX), combined with deep learning reconstruction (DLR). MATERIALS AND METHODS: In 80 consecutive patients, VORTEX with CR was performed for the axial, sagittal, and coronal planes with scan time of 84, 50, and 54 s, respectively, while VORTEX with PR was performed in the coronal (71 s) and sagittal planes (92 s), for a total of five imaging datasets. All datasets were reconstructed using a commercially available DLR (AIRTM Recon DL). Five radiologists performed image quality assessments. Inter-reader agreement was estimated using Gwet's AC2 statistics. RESULTS: All VORTEX derived images were assigned a T2w image PI-QUAL score of ≥3, and all radiologists perceived fewer artifacts in the sagittal and coronal PROPELLER images (p < .001). Four out of five radiologists also observed both superior overall image quality and reduced noise for all PROPELLER derived images (p < .001). Inter-rater agreement was good to very good for all assessments (AC2 0.77-0.88). CONCLUSION: VORTEX with PR and DLR can achieve fast high-quality T2w sagittal and coronal imaging of prostate, with all acquisitions completed within 95 s per imaging plane and a total triplanar acquisition time of 4 min 7 s.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accelerated Renal T2-Weighted Turbo Spin-Echo Imaging with Deep Learning Reconstruction: Reduced Acquisition Time and Improved Image Quality in Patients with Renal TumorsBioengineering · 2026
- Image quality evaluation of dual deep learning accelerated post-contrast Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging at 1.5 T and 3 T MRI.Acta radiologica (Stockholm, Sweden : 1987) · 2026
- Pre-Scan Breathing Pattern and Image Quality in Respiratory-Triggered T2-Weighted Liver MRI: Radial Versus Cartesian Fast Spin Echo.Journal of magnetic resonance imaging : JMRI · 2026
- ACCELERATED ANKLE MRI PROTOCOL USING COMBINED VARIABLE DENSITY UNDERSAMPLING OF K-SPACE WITH ECHO SPACING OPTIMIZATION le Density.Osteoarthritis imaging · 2026
- Single-shot T2-Weighted Turbo Spin-echo Imaging of the Liver Improves Lesion Characterization Compared with Free-breathing Acquisition.Academic radiology · 2026
- Deep Resolve Boost in 2D MRI for Neuroradiology: A Comparative Evaluation of Diagnostic Gains and Potential RisksAmerican Journal of Neuroradiology · 2025