The effect of Anesthesia Information Management Systems (AIMS) on perioperative epidural documentation: A retrospective cohort study.
Dulmi Nawarathna, John Shaker, Thomas P Wall
Department of Anaesthesiology & Perioperative Medicine, Mater Misericordiae University Hospital, Dublin, Ireland.
Key points
From the paper's conclusion- In our institution, completion of epidural documentation components is more consistent in AIMS compared to handwritten records, although local factors (e.g. user training) may limit the generalisability of this finding. Not including all desired elements on a single page can lead to user failure to document them in other areas of the AIMS chart. Such user behaviour should be considered when configuring AIMS interfaces.
Abstract
OBJECTIVES: Perioperative epidural documentation is an essential record of a procedure which has significant clinical and medico-legal implications. Little is known about the impact of the introduction of electronic Anesthesia Information Management Systems (AIMS) on the quality of epidural documentation compared to handwritten records. This study identifies elements of epidural documentation and, using a novel scoring system (Documentation Completion Score, DCS) quantifies the difference in documentation completeness between handwritten and AIMS records. METHODS: In a single-centre retrospective cohort study, 100 handwritten anesthesia records involving epidural placement were randomly selected from historic paper charts and a further 100 electronic records were randomly chosen from the AIMS database. All records retrieved were assessed for 15 pre-identified documentation components. DCS was calculated for each record and the groups were compared using inferential statistical tests. RESULTS: Of 15 documentation components, 11 were more consistently entered in AIMS compared to handwritten records. DCS was significantly higher in the AIMS group (13.48 ± 1.01, mean ± standard deviation) versus the handwritten group (9.91 ± 2.93), p < 0.001. Notably, the one element which was more consistently documented in handwritten records ('LA test dose documented') did not have a corresponding specific interface element in AIMS. CONCLUSION: In our institution, completion of epidural documentation components is more consistent in AIMS compared to handwritten records, although local factors (e.g. user training) may limit the generalisability of this finding. Not including all desired elements on a single page can lead to user failure to document them in other areas of the AIMS chart. Such user behaviour should be considered when configuring AIMS interfaces.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electronic patient blood management monitoring using routine health record data: A proof‐of‐principle study monitoring perioperative tranexamic acid useTransfusion · 2026
- Development and clinical implementation of a low-cost cloud-based electronic veterinary anesthesia record.Veterinary anaesthesia and analgesia · 2026
- Improving Abbreviated Mental Test Score Documentation in Acute Medical Admissions Using a Systems Engineering Initiative for Patient Safety.Cureus · 2026
- Association of electronic versus paper-based documentation with completeness of prehospital emergency physician reports in suspected acute coronary syndrome: a retrospective cohort analysis.International journal of emergency medicine · 2026
- Association of virtual nursing implementation with documentation completeness and interruptions in emergency departments.Journal of the American Medical Informatics Association : JAMIA · 2026
- Endotracheal Excellence: Standardizing Documentation to Drive Quality in Airway Rescue Procedures Across the Health System.Cureus · 2026