Improving Abbreviated Mental Test Score Documentation in Acute Medical Admissions Using a Systems Engineering Initiative for Patient Safety.
Kiransoy J Koikara, Betsy Babu
Accident and Emergency, Queen Elizabeth Hospital King's Lynn NHS Foundation Trust, Cambridge, GBR. · Internal Medicine, Medical University of Sofia, Sofia, BGR.
Key points
From the paper's conclusion- This quality improvement project aimed to improve documentation of the Abbreviated Mental Test Score (AMTS) in acute medical admissions and to explore staff-reported barriers using the Systems Engineering Initiative for Patient Safety (SEIPS) framework.
Abstract
Introduction Reliable documentation of cognitive screening is important in acute medical care because an absent result does not show whether screening was omitted, deferred, or completed but not recorded. This quality improvement project aimed to improve documentation of the Abbreviated Mental Test Score (AMTS) in acute medical admissions and to explore staff-reported barriers using the Systems Engineering Initiative for Patient Safety (SEIPS) framework. Methods This was a single-centre, two-cycle quality improvement project at an NHS hospital in England. The supplied project record describes an initial audit in March and a re-audit in June. The primary process measure was the proportion of audited records containing a completed AMTS form. Staff feedback was reviewed descriptively and mapped to person, task/technology, organisational, and environmental factors. A multicomponent improvement package included teaching, posters, awareness activities, and discussion at a grand round. The stated local target was 60% completion. Results At baseline, 28 of 60 records contained a completed AMTS form (46.7%). At re-audit, 40 of 58 records contained a completed form (69.0%), an absolute increase of 22.3 percentage points. The re-audit was 9.0 percentage points above the local 60% target. Between 00:00 and 07:59, completion increased from 2/11 (18.2%) to 4/10 (40.0%). Staff feedback identified competing clinical demands, fatigue, forgetting, uncertainty about expectations, reduced overnight staffing or supervision, and patients who were asleep or unable to engage. Conclusion Recorded AMTS completion was higher at re-audit after a package of education and awareness measures. The uncontrolled before-and-after design, modest sample, and incomplete documentation of implementation and governance limit causal interpretation. The findings support further local testing of workflow-linked prompts, clear task ownership, and a documented approach to clinically appropriate deferral.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving Clinical Efficiency Using Artificial Intelligence Scribe for Documentation ( ICE ‐ AID Study): A Retrospective‐Prospective Cohort Study at a Quaternary Children's Hospital and Health ServiceJournal of Paediatrics and Child Health · 2026
- Quantifying the Quality of Corrective Actions in Medical Safety Incident Reports Using a Hybrid Rule-Based and Large-Language-Model Classification System: A Cross-Sectional Pilot Feasibility Analysis of 11,507 Japanese National Reports (2010, Interim)medRxiv · 2026
- Crossover Evaluation of Two Ambient AI Scribe Tools in the Emergency DepartmentApplied Clinical Informatics · 2026
- Nurse-Led Ambient AI Scribe for Patient Safety Incident Investigation Reports (Project NARRATE): Retrospective Pre-Post Comparative Document-Quality Study.JMIR nursing · 2026
- Evaluation of a multi-professional therapy and monitoring system in acute geriatric care: a mixed methods studyQuality and User Experience · 2026
- Implementation of the Agitated Behavior Scale for Hospitalized Children With Acquired Brain Injuries: A Quality Improvement Initiative.The Journal of head trauma rehabilitation · 2026