Journal of children's orthopaedics

Locking-compression plate (LCP) or angled blade plates (ABP) for femoral osteotomies in children with spastic cerebral palsy (CP) gross motor function classification system (GMFCS) III, IV, and V.

Brandon Zaldivar, Laura Cecilia Ramirez-Schneider, Emma Isabel Balcázar-Muñoz, Nicolas Arango-Piedrahita, Juan Nicolas Macallister-Diaz, Mauricio Mafla-Gómez, Maria Fernanda Garcia-Rueda

Department of Orthopedic Surgery, Instituto Roosevelt, Bogotá, D. C., Colombia.

Observational · n=285

Key points

From the paper's conclusion
  • LCP and ABP demonstrate comparable hardware-related complication rates in children with CP undergoing femoral osteotomies. Recommendations on hardware selection for distal femoral osteotomy warrant larger studies in non-ambulatory patients.

Abstract

PURPOSE: To compare hardware-related complications and intraoperative variables between locking compression plates (LCP) and angled blade plates (ABP) used for proximal and/or distal femoral osteotomies in patients with spastic cerebral palsy (CP) classified as Gross Motor Function Classification System (GMFCS) III-V. METHODS: A retrospective cohort study was conducted, including patients younger than 18 years with spastic CP (GMFCS III-V) who underwent proximal and/or distal femoral osteotomies between 2015 and 2022. Demographic variables, plate type, operative time, blood loss, and hardware-related complications (implant failure, peri-implant fracture, and non-union) were recorded. Comparisons between groups were performed using generalized linear mixed-effects models to account for patients with multiple procedures. RESULTS: A total of 285 patients were included, with a mean follow-up of 23 months. Twenty-six complications occurred in 24 patients: 12 in the LCP group (4.9%) and 14 in the ABP group (3.6%). No significant differences were observed in overall complication rates between plate types for femoral osteotomies. All peri-implant fractures, implant failures, and non-unions at the distal femur were with ABP. LCP fixation was associated with longer operative time and greater blood loss. CONCLUSIONS: LCP and ABP demonstrate comparable hardware-related complication rates in children with CP undergoing femoral osteotomies. Recommendations on hardware selection for distal femoral osteotomy warrant larger studies in non-ambulatory patients. SIGNIFICANCE OF FINDINGS: Proximal femoral osteotomies in patients with CP can be performed with either hardware, with comparable complication rates; however, the focus of future studies should be on plate types for the distal femur.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers