Biomechanical comparison of suture materials across a bone tunnel edge.
Benjamin Basseri, David Shamritsky, Cristian Escalera, Scott W Wolfe
Hospital for Special Surgery, New York, USA.
Key points
From the paper's conclusion- Synthetic suture and tape constructs demonstrated differing mechanical properties and failure modes across a bone tunnel edge. Material selection and strand configuration may influence construct stiffness, elongation, and failure risk for ligament reconstruction.
Abstract
INTRODUCTION: Wrist reconstructive procedures commonly use synthetic materials passed through transosseous tunnels to stabilize the carpus. This experimental study compared the tensile mechanical properties of common sutures and synthetic tapes across a bone tunnel edge. We hypothesized that failure would primarily occur at the cortical bone edge owing to abrasion at the suture-bone interface and that increasing strand number would increase construct stiffness and decrease failure. METHODS: Five suture materials (SutureTape, LabralTape, FiberTape, Ethibond, and Mersilene) were tested in one-, two- and four-strand configurations, with 12 constructs per group. Constructs were passed through a 2.5 mm transverse tibial bone tunnel and secured to a servohydraulic testing apparatus with knotless fixation. Testing simulated physiologic scapholunate ligament loading with 1000 cycles from 0 to 100 N at 1.5 Hz followed by ramp loading to 300 N. One-way ANOVA with Tukey post hoc analysis (α = 0.05) evaluated load at failure and percentage elongation. RESULTS: Single-strand SutureTape, Mersilene and Ethibond demonstrated greater elongation at 100 N than single-strand LabralTape and FiberTape (p < 0.001). Mersilene and Ethibond elongated significantly more than SutureTape. Increasing strand number decreased elongation, although not proportionally to the number of strands. Single-strand Ethibond and Mersilene had the highest failure rates and lowest failure loads. No single- or double-strand LabralTape or FiberTape constructs failed at the bone tunnel edge. CONCLUSION: Synthetic suture and tape constructs demonstrated differing mechanical properties and failure modes across a bone tunnel edge. Material selection and strand configuration may influence construct stiffness, elongation, and failure risk for ligament reconstruction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Analysis of Rotator Cuff Repair: Comparison of Sutures and Fixation Techniques in a Synthetic Model.Cureus · 2026
- Allograft Strut Fixation to Humeral Bone: A Biomechanical Comparison of Suture-Tape Cerclage, Wire Cerclage, and Screws.Journal of shoulder and elbow surgery · 2026
- Suture Slippage Is Influenced by Suture Type and Bone Density in a Knotless Lateral Row Rotator Cuff Repair: A Biomechanical Analysis.Arthroscopy, sports medicine, and rehabilitation · 2026
- Three-Anchor Knotless Compression Bridges Improve Contact Mechanics in a Biomechanical Model of Large, Single-Row Tendon Repairs.Arthroscopy, sports medicine, and rehabilitation · 2026
- High-Tensile-Strength Suture Tape Provides Higher Load to Failure Than Conventional Suture for Glenoid Labral Repair in a Cadaveric Model.Arthroscopy, sports medicine, and rehabilitation · 2026