Failure Modes of Total Wrist Arthroplasty: Cross-Sectional Analysis of FDA MAUDE Adverse Event Reports (2015-2025).
Roban Shabbir, Brendan Layton, Zion Kang, Paulo Parente, David Riopelle, Luke Nicholson, Ali Azad
Temple University, Philadelphia, PA, USA. · NYU Langone Health, New York, NY, USA.
Key points
From the paper's conclusion- These findings describe submitted adverse events rather than true failure rates and reflect the limitations of passive reporting. Contemporary TWA continues to encounter substantial mechanical and fixation-related complications, highlighting the need for improved implant design, refined technique, and stronger post-market surveillance.
Abstract
BACKGROUND: Total wrist arthroplasty (TWA) is a motion-preserving alternative to wrist fusion for end-stage wrist arthritis, but concerns regarding long-term durability continue to limit broader use. Reported 10-year survivorship ranges from 70% to 80%, although real-world failure patterns remain poorly defined. METHODS: Adverse events were reviewed for TWA devices submitted to the U.S. Food and Drug Administration Manufacturer and User Facility Device Experience database from January 1, 2015, to September 30, 2025. Reports were identified using the wrist arthroplasty device code and confirmed by manufacturer and implant name. Nonwrist devices and duplicate submissions were excluded. Event narratives were manually reviewed and assigned a primary failure mode using a predefined taxonomy. Reports lacking sufficient detail were excluded from analyses. RESULTS: Among 313 unique reports with adequate information, loosening or component migration was the most common failure mode (37%), followed by dislocation or instability (18%) and infection (13%). Less common complications included tendon or nerve injury, polyethylene wear or metallosis, implant fracture, and periprosthetic fracture. Annual failure-mode reports peaked in 2022, with additional clustering in 2018 and 2019. Loosening/migration was most frequent in 2022, whereas dislocation/instability clustered in 2019. Manufacturer-year reporting was mostly by Stryker and Zimmer Biomet, though reports involved all manufacturer groups. CONCLUSIONS: These findings describe submitted adverse events rather than true failure rates and reflect the limitations of passive reporting. Contemporary TWA continues to encounter substantial mechanical and fixation-related complications, highlighting the need for improved implant design, refined technique, and stronger post-market surveillance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- All-Inside Meniscus Repair Systems Failure Analysis Shows Device-Related Adverse Events Differ by Device Design Type and Show Varied Reporting Delays by Manufacturer.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026
- Rising Revision Burden in Total Wrist Arthroplasty: National Medicare Trends and Projections to 2060.Hand (New York, N.Y.) · 2026
- First-in-human prospective pilot study of a bipolar dual-center total wrist arthroplasty: early mechanical stability and clinical outcomes.Archives of orthopaedic and trauma surgery · 2026
- Using the Lymphocyte Transformation Test to Diagnose Early Knee Arthroplasty Failures from Metal Hypersensitivity and Multidirectional Instability.Journal of surgical orthopaedic advances · 2026
- Failure modes of robotic-assisted arthroplasty platforms in Australia: a descriptive analysis of TGA adverse event reports.Journal of robotic surgery · 2026
- Registration and results reporting of interventional clinical trials for hand and wrist conditions: A cross-sectional analysis of 730 ClinicalTrials.gov recordsJournal of Musculoskeletal Surgery and Research · 2026