The CAST technique: A novel capture-assisted Safari tracking maneuver for radial pigtail repositioning after TAVI.
K Ouerghi, T Benard, S Dang Van, F Rouleau, F Pinaud, V Mateus, A Camarzana, W Abi Khalil,
Interventional Cardiology Department, Centre Hospitalier de Laval, Laval, France. Electronic address: ouerghi_kais@hotmail.fr. · Interventional Cardiology Department, Centre Hospitalier Universitaire d'Angers, Angers, France.
Key points
From the paper's conclusion- The CAST technique is a simple, reproducible, and equipment-free maneuver that can overcome selected difficulties encountered with radial access during minimalist TAVI. It may reduce repeated catheter and guidewire manipulation and avoid the need for additional femoral access.
Abstract
INTRODUCTION: Right radial access is increasingly used as the sole secondary arterial access during minimalist transcatheter aortic valve implantation (TAVI). However, unfavorable right subclavian-aortic arch angulation or marked supra-aortic tortuosity may prevent spontaneous advancement of a radial pigtail catheter into the descending aorta. TECHNIQUE: We describe the CAST (Capture-Assisted Safari Tracking) technique, a simple and reproducible maneuver for repositioning a radial pigtail catheter into the descending aorta using the Safari XS guidewire already in place during TAVI. The technique consists of four sequential steps: encounter, capture, pull-down, and release. The Safari XS guidewire acts as a traction rail, allowing the pigtail loop to be captured and guided in a controlled manner toward the descending aorta. RESULT: This maneuver enables successful repositioning of the pigtail catheter into the descending aorta despite unfavorable supra-aortic anatomy, without requiring additional arterial access or dedicated equipment. CONCLUSION: The CAST technique is a simple, reproducible, and equipment-free maneuver that can overcome selected difficulties encountered with radial access during minimalist TAVI. It may reduce repeated catheter and guidewire manipulation and avoid the need for additional femoral access.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Snare Assisted Guiding Catheter Stabilization for Left Internal Carotid Artery Access via Right Distal Radial Approach.Vascular and endovascular surgery · 2026
- Distal Radial Access for Thoracic Branch Endoprosthesis Deployment: Two Cases of Successful TEVAR with Left Subclavian Artery Revascularization.Reports (MDPI) · 2026
- Balloon-assisted crossing via trans-radial access during transcatheter aortic valve implantation: a case series demonstrating the BACTRA technique.European heart journal. Case reports · 2026
- Snare-Assisted Traction Technique for Renal Artery Reconstruction in Endovascular Repair of Complex Thoracoabdominal Aortic Aneurysms.JACC. Asia · 2026
- Transfemoral-TAVR Through Right Aortic Arch and Iliac Tortuosity: A Stepwise Guide to Overcoming Anatomical Barriers.JACC. Case reports · 2026
- Transaxillary Transcatheter Aortic Valve Replacement: A Technical Narrative.JACC. Case reports · 2026