A Novel Medical Conformity Index (MCI) Integrating Spatial Distance and Target Volume Weighting for Enhanced Radiotherapy Plan Evaluation.
Hye Jeong Yang, Chankyu Kim, Jason W Sohn, Dae Yong Kim, Sung Ho Moon, Dongho Shin, Young Kyoung Lim, Jong Hwi Jeong,
Proton Therapy Center, National Cancer Center Korea, Goyang-si, South Korea. · Department of Radiation Oncology, Allegheny Health Network, Pittsburgh, USA.
Key points
From the paper's conclusion- The results demonstrated that MCI can differentiate spatial conformity differences that may not be fully reflected by conventional conformity indices.
Abstract
IntroductionConventional conformity indices primarily quantify the geometric relationship between the target volume and the prescription isodose volume, which may not fully reflect clinically relevant dose deviations. This study aimed to develop a medical conformity index (MCI) that integrates geometric conformity with clinical considerations and to evaluate its performance in assessing radiotherapy plan quality.MethodsThe proposed MCI quantifies conformity by incorporating bidirectional local distance between the target volume (TV) and Prescription Isodose Volume (PIV) using an asymmetric Gaussian distance penalty function. Distinct penalty levels are assigned to under- and over-covered regions to reflect the clinical priority of target coverage and organ at risk (OAR) sparing. Additionally, a Target Volume Weight Function (TVWF) is integrated to ensure consistency across different target sizes, and OAR-specific constraints are introduced. The performance of the MCI was evaluated using synthetic 2D plans and clinical treatment plans, compared against conventional indices such as RTOG, SALT-Lomax, and CN.ResultsThe proposed MCI provided more consistent and clinically relevant scoring compared to conventional indices, particularly in cases with complex geometric discrepancies. Unlike existing metrics, the MCI demonstrated superior sensitivity to spatial differences and allowed flexible evaluation through user-defined penalty levels. Furthermore, the index enabled a robust assessment of plan quality by reflecting the clinical impact of dose distribution variations.ConclusionsThe proposed MCI provides a quantitative conformity measure that integrates bidirectional spatial distance, asymmetric penalties, and target volume weighting. The results demonstrated that MCI can differentiate spatial conformity differences that may not be fully reflected by conventional conformity indices. Further clinical validation is required to determine clinically meaningful penalty levels and acceptance criteria.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Towards consensus on practical probabilistic evaluation metrics for clinical decision making in radiotherapyarXiv · 2026
- Statistical process control and error curve modelling identify superior pre-treatment verification metrics for nasopharyngeal carcinoma and cervical cancer VMAT: a retrospective studyFrontiers in Oncology · 2026
- AI-assisted Treatment Planning - Only a Vision? A Laboratory Proof-of-Concept in Complex Radiotherapy Treatment Planning Using a Large Language Model for Dose Optimization.Anticancer research · 2026
- A first application of split conformal prediction for dose prediction in knowledge-based radiotherapy planningarXiv · 2026
- Multi-criteria inverse robustness in radiotherapy planning using semidefinite programmingOR Spectrum · 2026
- Uncertainty-Aware Multiscale Treatment Response Forecasting in Advanced Non-Small Cell Lung Cancer Using Residual-Variance Conformal Prediction.medRxiv : the preprint server for health sciences · 2026