Portable Electrical Impedance Prescreening for Breast tissue suspicious for malignancy: Model Optimization and Clinical Performance of the Julieta Device in a Multicenter Cross-Sectional Study in Colombia
María Andrea Negret, Valentina Villegas González, David Grajales, Maria Alejandra Velez, Maria Alejandra Yepez, Valentina Agudelo, Sergio Lopez, Clara Piedrahita
Pontificia Universidad Javeriana · Municipality of Medellín
Key points
From the paper's conclusion- This study assessed the performance of a hierarchical algorithm integrated into JULIETA to distinguish findings without malignant potential (BI-RADS 1-2) from those with malignant potential (BI-RADS ≥3), using mammography as the reference standard.MethodsA cross-sectional observational study with prospective data collection was conducted between May and July 2024 in four Colombian cities.
Abstract
IntroductionBreast cancer remains a leading cause of cancer mortality despite being potentially curable when detected early, particularly in low- and middle-income countries where access to screening is limited. This is largely driven by operational gaps, including limited access to screening and delays in diagnosis and treatment. JULIETA is a portable bioimpedance spectroscopy device designed to identify electrical tissue patterns associated with potentially malignant findings and to prioritize women for further diagnostic evaluation. This study assessed the performance of a hierarchical algorithm integrated into JULIETA to distinguish findings without malignant potential (BI-RADS 1-2) from those with malignant potential (BI-RADS ≥3), using mammography as the reference standard.MethodsA cross-sectional observational study with prospective data collection was conducted between May and July 2024 in four Colombian cities. Adult women undergoing screening or follow-up mammography were evaluated with JULIETA prior to imaging. Impedance-derived features, breast density estimates, and individual risk scores were used to retrain a hierarchical classifier combining Random Forest and SVM-RBF models, using an 80/20 stratified split and cross-validation.ResultsA total of 1350 women were recruited (mean age 56.5 ± 8.0 years); 67% were BI-RADS 1-2 and 21% BI-RADS 4. After data cleaning, 673 breasts (469 women) were included. The model achieved 73% sensitivity, 76% specificity, 65.5% positive predictive value, and 82.1% negative predictive value.ConclusionJULIETA is a feasible, safe, and reproducible noninvasive bioimpedance pre-screening tool that may enable scalable triage and support earlier detection and improved equity when integrated into public health pathways.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radiomics-based analysis of pre-symptomatic screening mammograms associated with future breast cancer occurrence in a Japanese screening population.Radiological physics and technology · 2026
- Simultaneous Preoperative Prediction of Locally Advanced Breast Cancer, DCIS Component, and Multifocality Using Structured Mammographic Features and Gradient-Boosting Machine Learning.Diagnostics (Basel, Switzerland) · 2026
- Bioelectrical Impedance Analysis for Severity Assessment of Cancer-associated Secondary Lymphedema: A Large-cohort Validation against ISL and Lymphoscintigraphy Staging in Gynecologic Cancer Survivors.Journal of reconstructive microsurgery · 2026
- Evaluation of a Mammography-based Deep Learning Model for Breast Cancer Risk Prediction in a Triennial Screening ProgramRadiology · 2025
- Comprehensive Radiomics Analysis to Enhance Breast Lesion Characterization Using QUS Spectral Parametric Imaging.Cancers · 2026
- Diagnostic performance of quantitative shear-wave elastography for reclassifying BI-RADS category 4 breast lesions: a retrospective single-center study.Frontiers in public health · 2026