Diagnostic performance of quantitative shear-wave elastography for reclassifying BI-RADS category 4 breast lesions: a retrospective single-center study.
Manlong Long, Henghua Xiao, Jun Yang, Mouhai He, Lingli Hu
Department of Ultrasound Medicine, Hengyang Central Hospital, Hengyang, Hunan, China. · College of Medical Technology and Nursing, Hunan Institute of Traffic Engineering, Hengyang, Hunan, China.
Key points
From the paper's conclusion- Objective To evaluate four quantitative shear-wave elastography (SWE) parameters (Emax, Emean, Emin, elasticity ratio) for differentiating benign and malignant BI-RADS 4 breast lesions and reclassifying lesions that may potentially avoid immediate biopsy.
Abstract
OBJECTIVE: To evaluate four quantitative shear-wave elastography (SWE) parameters (Emax, Emean, Emin, elasticity ratio) for differentiating benign and malignant BI-RADS 4 breast lesions and reclassifying lesions that may potentially avoid immediate biopsy. METHODS: This single-center retrospective analysis enrolled 454 pathologically confirmed BI-RADS 4 lesions (one per patient) examined with conventional ultrasound and SWE (2022-2025). BI-RADS subcategories (4A/4B/4C) were determined prior to SWE acquisition, and Emax, Emean, Emin, Eratio were recorded. A multivariable logistic regression model was developed. Receiver-operating characteristic (ROC) analysis and paired DeLong test evaluated discrimination, with bootstrap resampling for internal validation. RESULTS: Of the 454 lesions, 277 (61.01%) were benign, and 177 (38.99%) were malignant. All four SWE parameters were higher in malignant than in benign lesions (all p < 0.001) and remained independent predictors of malignancy [Emax: odds ratio (OR), 1.106 (95% confidence interval (CI), 1.073-1.140); Emean: OR, 1.115 (95% CI, 1.080-1.152); Emin: OR, 1.101 (95% CI, 1.053-1.151); and Eratio: OR, 2.438 (95% CI, 1.875-3.170), per 1-kPa/1-unit increment; all p < 0.001]. The combined model achieved an AUC of 0.948 (95% CI, 0.926-0.970), with a sensitivity of 84.75% and a specificity of 93.86%, and outperformed each individual parameter (all p < 0.001); the bootstrap optimism-corrected AUC was 0.945. When the model probability was used as a standalone post-hoc exploratory rule (cut-off p = 0.32), 255 lesions (56.17%) were classified as low-risk; this group nevertheless contained 17 malignant lesions (apparent negative predictive value, 93.33%; missed-cancer rate, 9.60%; bootstrap-corrected, 92.96% and 10.14%, respectively). The rule therefore did not demonstrate that immediate biopsy could be safely avoided. CONCLUSION: Quantitative SWE parameters differentiated benign and malignant BI-RADS 4 lesions, with the four-parameter combined model achieving better discrimination than single parameters. The reclassification strategy may potentially reduce benign biopsies if validated prospectively. Given the absence of external validation, these preliminary findings require prospective multicenter confirmation before clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Shear Wave Elastography for Characterization of Breast Lesions in Clinical RoutineJournal of Ultrasound in Medicine · 2026
- Shear-wave elastography combined with ultrasound BI-RADS improves diagnostic accuracy in breast lesion characterization: a prospective cross-sectional study.Journal of ultrasound · 2026
- Quantitative Shear-Wave Elastography in Prostate Cancer: Lesion-Level Stiffness Thresholds and Association with Histopathological Aggressiveness.Cancers · 2026
- Added Value of Shear Wave Elastography for Noninvasive Detection of Axillary Lymph Node Metastasis and IHC-Defined Surrogate Subtype Characterization in Breast Cancer.Cancers · 2026
- (Elastography) E-BI-RADS: A Novel Classification System for Breast Elastography to Enable Safe Biopsy De-escalation.Investigative radiology · 2026
- Diagnostic Utility of Quantitative Strain Elastography in Breast Lesions: A Comparative Evaluation of Distance Ratio and Strain Ratio.Cureus · 2026