Bilateral Iliac Branch Endoprosthesis Deployment With IVUS-Guided Contrast-Sparing Technique: A Complex Case Report.
Bachar Al Haj, Charlott E Koehler, Martin J Austermann
Department of Vascular and Endovascular Surgery, St. Franziskus Hospital Muenster, Germany.
Key points
From the paper's conclusion- Intravascular ultrasound-guided bilateral IBE is feasible and substantially reduces contrast exposure in patients with renal impairment, though technical flexibility is essential for complex anatomy.Clinical ImpactIVUS-guided bilateral iliac branch endoprosthesis deployment may offer a contrast-sparing option for patients with chronic kidney disease undergoing endovascular repair of complex aortobiiliac aneurysms. Using IVUS for vessel identification, sizing, landing-zone selection, and stent-apposition assessment can reduce reliance on iodinated contrast while preserving internal iliac artery perfusion. This case shows that bilateral reconstruction is feasible with only 38 mL of contrast, even when complex anatomy requires axillary access. Its innovation is using IVUS as the primary guidance modality, with angiography reserved for confirmation and troubleshooting.
Abstract
BACKGROUND: Preserving internal iliac artery (IIA) patency during endovascular aortic repair (EVAR) for aortobiiliac aneurysms typically requires substantial contrast volume, posing risk to patients with renal insufficiency. CASE DESCRIPTION: We present the case of an elderly female with chronic kidney disease (CKD) stage 3b (baseline estimated glomerular filtration rate 35 mL/min/1.73 m², serum creatinine 1.5 mg/dL) and an aortobiiliac aneurysm who underwent complex bilateral iliac side-branch (iliac branch endoprosthesis [IBE]) deployment. The procedure used intravascular ultrasound (IVUS) as the primary guidance to minimize contrast exposure. A notable intraoperative challenge arose on the left side, where retrograde cannulation was unsuccessful due to anatomical tortuosity and sheath dislodgement. We therefore performed a left axillary cut-down, which facilitated successful IIA reconstruction and resolved a type 1b endoleak. The total contrast volume employed was approximately 38 mL. Incidental findings included hyperthyroidism and suspected lymphoproliferative disorder. CONCLUSION: Intravascular ultrasound-guided bilateral IBE is feasible and substantially reduces contrast exposure in patients with renal impairment, though technical flexibility is essential for complex anatomy.Clinical ImpactIVUS-guided bilateral iliac branch endoprosthesis deployment may offer a contrast-sparing option for patients with chronic kidney disease undergoing endovascular repair of complex aortobiiliac aneurysms. Using IVUS for vessel identification, sizing, landing-zone selection, and stent-apposition assessment can reduce reliance on iodinated contrast while preserving internal iliac artery perfusion. This case shows that bilateral reconstruction is feasible with only 38 mL of contrast, even when complex anatomy requires axillary access. Its innovation is using IVUS as the primary guidance modality, with angiography reserved for confirmation and troubleshooting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intravascular Ultrasound (IVUS)-Assisted Fenestrated Endovascular Aortic Repair (FEVAR) for Iuxtarenal Aortic Aneurysm with Pelvic Ectopic Left Kidney and Aberrant Left Renal Arteries: A Case Report.Reports (MDPI) · 2026
- Transarterial Computed Tomographic Angiography in Patients With Impaired Renal Function Undergoing Endovascular Aortic Repair.Vascular and endovascular surgery · 2026
- Endovascular and Hybrid Revascularisation for Concomitant Abdominal Aortic Aneurysm and Iliac Chronic Total Occlusion.Annals of vascular surgery · 2026
- Impact of Intravascular Ultrasound on Contrast Volume and Radiation Exposure in Endovascular Aortic Repair: A Retrospective Cohort Study.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Usefulness of Preoperative Renal Scintigraphy for Treatment Planning before Endovascular Repair of an Abdominal Aortic Aneurysm with a Horseshoe Kidney: A Case Report.Surgical case reports · 2026
- Early Outcomes of Physician-Modified Endurant Limbs vs Iliac Branch Devices in Narrow Common Iliac Arteries: A Retrospective Cohort Pilot Study.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026