Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

Impact of Intravascular Ultrasound on Contrast Volume and Radiation Exposure in Endovascular Aortic Repair: A Retrospective Cohort Study.

Yusuke Ki, Toru Kuratani, Yuki Oga, Naoya Kurata, Yasuka Nakanishi, Mitsuru Yuzaki, Taku Toyoshima, Tomohiko Sakamoto,

Department of Radiologic Technology, Osaka Keisatsu Hospital, Osaka, Japan. · Department of Cardiovascular Surgery, Aortic and Vascular Center, Osaka Keisatsu Hospital, Osaka, Japan.

Observational · n=71

Key points

From the paper's conclusion
  • IVUS use during EVAR was associated with reduced contrast volume and radiation exposure without prolonging procedure or fluoroscopy time. No statistically significant difference in early high-flow endoleaks was observed, although the small number of events limits conclusions regarding safety. IVUS may serve as a valuable adjunct in EVAR for reducing contrast use and radiation exposure.

Abstract

BACKGROUND: In endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm, contrast use and radiation exposure remain important clinical and occupational concerns. Intravascular ultrasound (IVUS) has been proposed as an adjunct that may reduce contrast requirements and radiation dose. AIMS: This study evaluated the impact of IVUS on contrast volume and radiation exposure-dose-area product (DAP) and air kerma (AK)-and explored its association with early high-flow endoleaks (Type I/III). METHODS: This retrospective observational study analyzed 95 consecutive infrarenal EVARs performed between August 2023 and September 2025. Primary outcomes were contrast volume and DAP; secondary outcomes were AK, fluoroscopy time, and procedure time. High-flow Type I/III endoleaks within 30 days were assessed as an exploratory outcome. Inverse probability weighting was applied to adjust for baseline imbalance. RESULTS: IVUS was used in 71 cases and not used in 24. Compared with No-IVUS, the IVUS group showed lower contrast volume (19 [13.5-29.5] mL vs. 37.5 [29.5-52.8] mL, p < 0.001), DAP (119.3 [88.2-160.1] Gy·cm2 vs. 203.2 [147.5-273.4] Gy·cm2, p < 0.001), and AK (444.5 [341.2-635.4] mGy vs. 832.9 [466.6-1043.3] mGy, p < 0.001). Fluoroscopy and procedure times were similar. Early Type I/III endoleaks occurred in 2/68 versus 2/24 (p = 0.278). CONCLUSION: IVUS use during EVAR was associated with reduced contrast volume and radiation exposure without prolonging procedure or fluoroscopy time. No statistically significant difference in early high-flow endoleaks was observed, although the small number of events limits conclusions regarding safety. IVUS may serve as a valuable adjunct in EVAR for reducing contrast use and radiation exposure.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Impact of Intravascular Ultrasound on Contrast Volume and Radiation Exposure in Endovascular Aortic Repair: A Retrospective Cohort Study — Science Skim