Roadmap to Fully Closing the Loop to Optimize Health in Type 1 Diabetes.
Brynn E Marks, Marisa E Hilliard, Boris Kovatchev, Othmar Moser, Molly L Tanenbaum, Courtney Ackeifi, David T Ahn, Ramzi A Ajjan,
Breakthrough T1D, New York, New York, USA. · Department of Pediatrics, Division of Psychology, Baylor College of Medicine and Texas Children's Research Institute, Texas Children's Hospital, Houston, Texas, USA.
Key points
From the paper's conclusion- This framework provides a uniform benchmark for evaluating future FCL technologies. Taken together, this person-centered, outcome-driven framework holds that FCL systems should (1) autonomously attain near-normoglycemia, (2) meaningfully improve lived experience across the lifespan and clinical contexts, and (3) prevent exercise-related hypoglycemia.
Abstract
OBJECTIVE: Current commercially available automated insulin delivery systems require meal and exercise announcements for optimal function, placing them in the hybrid closed loop category. Ongoing advancements aim to establish fully closed loop (FCL) systems as the next-generation standard for type 1 diabetes (T1D) management, eliminating the need for such inputs. We sought to develop a shared definition of FCL so that emerging technologies, including those using artificial intelligence, multi-hormone delivery, multi-analyte sensing, and/or adjunctive therapies, are held to uniform performance standards. METHODS: A group of invited experts, including clinicians, researchers, and people with lived experience convened to propose an outcome-driven definition of FCL systems. RESULTS: FCL systems are defined by three core domains centered on meeting intensive glycemic targets while reducing self-management burden and improving lived experience: Time in Tight Range (TITR) 70-140 mg/dL (3.9-7.8 mmol/L), Time Below Range (TBR) <54 mg/dL (<3.0 mmol/L), and person-reported outcomes (PROs) measured with validated T1D-specific assessments. This definition rests on a three-tiered classification in which all FCL systems improve lived experience and attain >50% TITR and <1% TBR without mandatory meal or activity announcements. Class 3 systems must attain >50% TITR; Class 2, >70%; and Class 1, >90%-while simultaneously demonstrating improved quality of life and reduced treatment burden per validated PROs. Given the elevated hypoglycemia risk from insulin-on-board during exercise, Class 1a requires >90% TITR with demonstrable hypoglycemia prevention during standardized exercise testing (0% TBR). CONCLUSION: This framework provides a uniform benchmark for evaluating future FCL technologies. Taken together, this person-centered, outcome-driven framework holds that FCL systems should (1) autonomously attain near-normoglycemia, (2) meaningfully improve lived experience across the lifespan and clinical contexts, and (3) prevent exercise-related hypoglycemia.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Pancreas and Closed-Loop Insulin Delivery: From Early Concepts to AI-Driven Diabetes Automation.Biosensors · 2026
- Sustained Glycemic Outcomes in Children: A Three-Year Real-World Follow-Up of the MiniMed™ 780G System.Hormone research in paediatrics · 2026
- Discordant real‐world glycaemic outcomes with Omnipod™ 5 and MiniMed™ 780G in adults with type 1 diabetes: Why validated measures matterDiabetes Obesity and Metabolism · 2026
- A retrospective observational study evaluating the safety and effectiveness of commercially available automated insulin delivery systems in people with type 1 diabetes and gastroparesisDiabetes Obesity and Metabolism · 2026
- Prospective multicenter evaluation of glycemic and patient-reported outcomes following transition to a next-generation continuous glucose monitoring system in users of advanced hybrid closed-loop technologyTherapeutic Advances in Endocrinology and Metabolism · 2026
- Priorities, Expectations, Perceptions of Time in Tight Range and Support Needs Relating to Closed-Loop Therapy Among Adults With Type 1 Diabetes: The SELECT HCL Study.Diabetes, obesity & metabolism · 2026