Biomarker insights

Visual Confirmation of Residual Erythrocytes and Platelets in Human Plasma.

Mendel Engelaer, Rienk Nieuwland, Edwin van der Pol, Jillian W P Bracht

Department of Biomedical Engineering and Physics, Amsterdam UMC, Amsterdam, Netherlands. · Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam UMC, Location University of Amsterdam, Amsterdam, The Netherlands.

Key points

From the paper's conclusion
  • For the first time, we linked flow cytometry measurements of cells in double-centrifuged plasma to super-resolution microscopy images, thereby providing a visual confirmation of the presence of erythrocytes and platelets. The presence of these cells further underscores the need to account for them in EV-focused biomarker exploration.

Abstract

BACKGROUND: Human plasma stored in biobanks serves as a starting material for many biomarker studies. Despite being termed "platelet-free plasma", plasma still contains erythrocytes and platelets at concentrations below the limit of detection of routine haematology analysers, approximately 106 mL-1. The presence of these residual cells affects biomarker studies of extracellular vesicles (EVs). In previous work, we used flow cytometry to study residual cells in double-centrifuged plasma. However, because direct visualization of such low cell concentrations is technologically challenging, residual cells detected by flow cytometry in plasma have not yet been directly visualized. OBJECTIVES: Our goal is to visualize residual erythrocytes and platelets in double-centrifuged plasma and confirm that the flow cytometry events we previously detected indeed correspond to these cell types. DESIGN & METHODS: We developed a workflow combining cell sorting, flow cytometry, and super-resolution microscopy to enrich and image residual erythrocytes and platelets, and applied it to the plasma of a single donor. RESULTS: Flow cytometric analysis from the plasma of a healthy donor revealed concentrations of 4.5×105 mL-1 for erythrocytes and 3.05×105 mL-1 for platelets, consistent with previous reports. Sorting enriched these cells by 64-fold and 40-fold, respectively, enabling super-resolution microscopic imaging. Microscopy confirmed the presence of activated erythrocytes expressing CD235a and platelets expressing CD63. CONCLUSIONS: For the first time, we linked flow cytometry measurements of cells in double-centrifuged plasma to super-resolution microscopy images, thereby providing a visual confirmation of the presence of erythrocytes and platelets. The presence of these cells further underscores the need to account for them in EV-focused biomarker exploration.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers