Clinical Chemistry

A-308 Residual Platelets: An Underestimated Pre-analytical Challenge in Circulating Biomarker Research

Jing Li, Eunju Seong, Rachel Miller, Tyler Morris

Key points

From the paper's conclusion
  • Conclusion Residual platelets represent a critical, yet underestimated pre-analytical variable in circulating biomarker research.

Abstract

Background Circulating biomarkers, including soluble proteins and extracellular vesicles (EVs), are widely used in clinical diagnostics and biomarker research. However, pre-analytical variables including blood collection tube type, plasma processing protocols, and platelet (PLT) contamination can critically impact the accuracy and reliability of biomarker measurements. PLTs are small, highly abundant and densely granulated. They also serve as a major reservoir of circulating proteins, EVs, and EV-associated cargos (e.g., exoRNA). Residual PLTs in plasma are often overlooked and can artificially elevate biomarker signals through activation or lysis during processing and storage. This study systematically evaluates the impact of residual PLT in various blood collection tubes and explores the impact of different processing methods on biomarker abundance and stability. Methods Blood from matching self-proclaimed healthy donors was collected into EDTA, ACD-A, and Protein Plus BCT™ and stored at ambient temperature for up to 5 days to mimic delayed clinical processing. Plasma was isolated using either single-spin (1100–1300 × g, 10 min) or double-spin (1800 × g, 15 min; 2800 × g, 15 min) protocols. Residual PLT levels were quantified using a Sysmex XN-1000 hematology analyzer, and PLT-EV in plasma was analyzed using flow cytometry. PLT-associated protein abundance and stability were assessed over time using Proteograph™ XT workflow (Seer) coupled with Orbitrap™ Exploris™ 240 mass spectrometry or Ella™ Simple Plex™ assay (Bio-Techne). Results The double-spin protocol consistently reduced residual PLT in plasma compared to single-spin methods across all tubes. Compared to EDTA, ACD-A tubes effectively limit platelet activation when plasma is isolated within a short processing window. Protein Plus BCT demonstrated consistently low and stable residual PLT counts in plasma over time, with flow cytometry confirming stabilization of platelet derived EVs. Platelet associated proteins showed similar trends. For example, the Arp2/3 complex, a seven protein regulator of actin cytoskeleton remodeling in platelets, displayed a 2.8-fold higher abundance in single-spin EDTA plasma compared with double-spin EDTA plasma at draw time. Even with double-spin processing, EDTA plasma exhibited a 2.9-fold higher Arp2/3 abundance than Protein Plus BCT plasma. Over five days of ambient whole blood storage, EDTA plasma resulted in progressive increases in Arp2/3 complex proteins (5.2-fold for double-spin and 5.0-fold for single-spin processing), consistent with platelet activation or lysis. In contrast, Arp2/3 in Protein Plus BCT plasma remained stable from draw time, with minimal changes observed regardless of processing method. Conclusion Residual platelets represent a critical, yet underestimated pre-analytical variable in circulating biomarker research. Anticoagulant choice, plasma processing strategy, and storage duration significantly influence PLT contamination and biomarker accuracy and stability. Protein Plus BCT combined with double-spin plasma processing effectively minimizes residual platelets and preserves PLT-sensitive biomarkers. Standardizing mitigation of residual platelet effects is essential for robust and reproducible plasma-based biomarker analyses. Protein Plus BCT is for Research Use Only. Not for use in diagnostic procedures. Protein Plus BCT should only be used for research or the development of new assays.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-308 Residual Platelets: An Underestimated Pre-analytical Challenge in Circulating Biomarker Research — Science Skim