Completion angiography and venous outflow assessment in arteriovenous graft placement: A retrospective observational study.
Letty V van Vliet, Rutger J Brans, Willemien van de Water, Tammo Delhaas, Maarten G Snoeijs
Department of Vascular Surgery, Maastricht University Medical Centre+, Maastricht, The Netherlands. · Department of Radiology, Maastricht University Medical Centre+, Maastricht, The Netherlands.
Key points
From the paper's conclusion- Vein diameter, ranging from 1.5 to 15 mm, did not predict clinical outcomes, suggesting using smaller veins than the recommended 4 mm-threshold may be reasonable in patients with limited access options. In contrast, completion angiography proved useful by prompting intra-operative revisions and by detecting outflow abnormalities that are associated with later reinterventions. Venous outflow, rather than vein diameter alone, should guide surgical decision making in arteriovenous graft placement.
Abstract
OBJECTIVE: Arteriovenous grafts are frequently used for hemodialysis access. Optimizing graft placement is important to prevent thrombosis and reinterventions. This study evaluated the association between vein diameter and clinical outcomes and evaluated the diagnostic value of completion angiography. METHODS: This retrospective single-centre study included 113 patients who underwent graft placement between 2010 and 2017. Outflow vein diameter was measured preoperatively by duplex ultrasound and intraoperatively by angiography. Angiographies were also analyzed for abnormalities. Outcomes included early graft failure (loss of primary patency within 30 days), secondary patency and access-related intervention rates. Predictive accuracy of vein diameter was assessed with ROC curves. Categorical variables were analyzed with chi square tests; Kaplan-Meier curves with log-rank tests, and event rates with Poisson analysis. RESULTS: Neither duplex nor angiography-measured vein diameters were associated with early graft failure (ROC AUC 0.63, 95% CI: 0.41-0.85, p = 0.24; and ROC AUC 0.54, 95% CI: 0.40-0.69, p = 0.57) or secondary patency (HR 1.07 per mm, 95% CI 0.84-1.38 and HR 1.06, 95% CI 0.96-1.18 respectively). Using the 4-mm cutoff recommended in clinical practice guidelines, vein diameter was not associated with access-related intervention rates. Completion angiography led to immediate revision in 15% of cases. Venous outflow abnormalities were present in 63% of final completion angiographies and were associated with higher intervention rates during follow-up (3.26 vs 2.58 per patient-year, p = 0.01), but not with early graft failure or 12-month secondary patency. CONCLUSIONS: Vein diameter, ranging from 1.5 to 15 mm, did not predict clinical outcomes, suggesting using smaller veins than the recommended 4 mm-threshold may be reasonable in patients with limited access options. In contrast, completion angiography proved useful by prompting intra-operative revisions and by detecting outflow abnormalities that are associated with later reinterventions. Venous outflow, rather than vein diameter alone, should guide surgical decision making in arteriovenous graft placement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation and comparison of patency rate and complications of synthetic arteriovenous grafts in the groin and upper extremities among hemodialysis patients.Journal of research in medical sciences : the official journal of Isfahan University of Medical Sciences · 2026
- Two-Year Patency and Reintervention Patterns of Stent Graft Placement for Arteriovenous Graft Outflow Stenosis From a Prospective Multicenter Study.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026
- Dacron vascular grafts: a long-term solution for short renal vein challenges in living donor kidney transplantation in a retrospective case series.Annals of surgical treatment and research · 2026
- Explantation rates and failure mechanisms in early cannulation grafts: A comparative study between Flixene and Gore Acuseal.The journal of vascular access · 2026
- Association of hemodialysis vascular access type with dialysis adequacy and access-related outcomes in patients receiving maintenance hemodialysis.Frontiers in medicine · 2026
- Distal vein ligation in radiocephalic arteriovenous fistula creation: A randomized trial of hemodynamic impact and early maturation.The journal of vascular access · 2026