The journal of vascular access

Identification and management of secondary PICC malposition to the azygos vein during esophageal cancer resection: A report of three cases.

Chen Qian, Youxiang Bu, Wenjing Zhu, Xiangmei Sun, Ruchun Shi, Lianbing Gu, Liuliu Zhang

Operating Room, Jiangsu Cancer Hospital, Jiangsu Institute of Cancer Research, The Affiliated Cancer Hospital of Nanjing Medical University, Nanjing, China. · Vascular Access Clinic, Jiangsu Cancer Hospital, Jiangsu Institute of Cancer Research, The Affiliated Cancer Hospital of Nanjing Medical University, Nanjing, China.

Case report · n=3

Key points

From the paper's conclusion
  • Therefore, for esophageal cancer surgery patients requiring special body positions, it is recommended to re-evaluate the position of the catheter tip for secondary malposition after positioning and before azygos vein ligation.

Abstract

This article reports three cases of esophageal cancer patients in which peripherally inserted central catheter (PICC) were found to be involved in the azygos vein during surgery. Among them, two cases experienced catheter disconnection during azygos vein ligation, and one case was identified before ligation. The cases suggest that the key issue of this event lies in the accurate identification and handling of PICC tip displacement. Our center routinely uses intracardiac electrocardiogram (IC-ECG) to assess the position of the PICC tip and combines chest X-rays for confirmation. However, chest X-rays have a time lag; IC-ECG can indicate whether the catheter tip has reached the appropriate upper vena cava segment or junction of the atrium and ventricle, but it cannot clearly identify the specific vessel where the displacement has occurred. Therefore, for esophageal cancer surgery patients requiring special body positions, it is recommended to re-evaluate the position of the catheter tip for secondary malposition after positioning and before azygos vein ligation. When suspecting that the PICC catheter is located in the azygos vein, the surgeon and the surgical team members should communicate immediately, remind each other of the risks before azygos vein ligation; if the PICC catheter is damaged, it must be confirmed that the catheter integrity is intact to ensure no residue. Among the three cases in this group, two cases experienced catheter disconnection but were completely removed; the other case was identified and retreated before ligation; all patients were followed up for 1 month after surgery, and no catheter-related abnormalities were found.

Read the paper