Association between cementless femoral stem geometry and early aseptic loosening following primary total hip arthroplasty.
Regina Chi, Jawad J Najdawi, Andrew P Nakla, Rebecca G Burr, Sean S Rajaee
Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
Key points
From the paper's conclusion- Single-taper stems demonstrated higher rates of return to the OR and revision for femoral aseptic loosening during the 2-year postoperative period. Surgeons should consider these findings when selecting femoral stem designs for elderly patients who plan to undergo cementless primary THA.
Abstract
BACKGROUND: Aseptic loosening is a significant complication following total hip arthroplasty (THA), particularly in geriatric patients with diminished bone quality. Femoral stem design in cementless primary THA for osteoarthritis (OA) plays a crucial role in mitigating this risk. This study examined the impact of stem geometry on early aseptic loosening. We hypothesised that single-taper (wedge) stems are associated with higher rates of early aseptic loosening. METHODS: We retrospectively analysed 2952 cementless primary THA procedures at a single institution between November 2013 and December 2021. Patients ⩾ 65 years old who underwent primary THA for OA were included. Patients with preoperative diagnoses of fracture, avascular necrosis (AVN), or bone neoplasia, and those with periprosthetic fracture (PPF) within 90 days of index procedure were excluded. Femoral stems were categorised into 4 groups: (1) single-taper (wedge); (2A) collarless dual- and triple-taper; (2B) collared dual- and triple-taper; and (3) fit-and-fill. 2-year rates of femoral aseptic loosening as well as return to operating room (OR) were assessed. RESULTS: The study consisted of 1000 single-taper stems, 1185 collarless dual- and triple-taper stems, 213 collared dual- and triple-taper stems, and 554 fit-and-fill stems. Single-taper stems had significantly higher rates of aseptic loosening (0.8% vs. 0.2%) and overall return to the OR (2.6% versus 1.1%). CONCLUSIONS: Single-taper stems demonstrated higher rates of return to the OR and revision for femoral aseptic loosening during the 2-year postoperative period. Surgeons should consider these findings when selecting femoral stem designs for elderly patients who plan to undergo cementless primary THA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Collared Stems Are Associated With Reduced Early Aseptic Loosening and All-Cause Revision Rate.The Journal of arthroplasty · 2026
- Aseptic loosening of small hydroxyapatite-coated quadrangular tapered femoral stems: camouflage in the Canadian Joint Replacement Registry.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- The Triple-Tapered Uncemented Femoral Stems in Slight Varus Demonstrated Excellent Early Survivorship and Clinical Results.The Journal of arthroplasty · 2026
- Periprosthetic strain-adaptive bone remodeling of conservative metaphyseal fitting versus conventional anatomic cementless femoral stem.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- Ten-year migration analysis of a cementless metaphyseal-anchored short femoral stem in total hip arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Collared, Uncemented Stems Markedly Reduce Periprosthetic Femoral Fracture Risk in Women ≥ 70 Years: A Swiss National Registry Study.The Journal of arthroplasty · 2026