Key points
From the paper's conclusion- One eye (16.7%) developed partial inferior IOL subluxation, without associated visual or refractive deterioration, and two eyes (33.3%) developed cystoid macular edema, resolved with treatment.ConclusionIn this small proof-of-concept series, the double-rectangle 10-0 prolene suture technique allowed repositioning of dislocated rigid C-loop PMMA IOLs while avoiding a large corneal incision and was
Abstract
PurposeTo describe a novel technique for repositioning dislocated rigid C-loop polymethyl methacrylate (PMMA) intraocular lenses (IOLs) without eyelets using a double-rectangle 10-0 prolene suture configuration.MethodsThis retrospective observational study included six eyes of patients with dislocated rigid C-loop PMMA IOLs in the vitreous cavity. All eyes underwent pars plana vitrectomy and repositioning of the existing IOL using a double-rectangle 10-0 prolene suture configuration, securing the IOL between the suture and the iris. Postoperative evaluation included best-corrected visual acuity (BCVA), slit-lamp biomicroscopy, fundoscopy, anterior segment optical coherence tomography (AS-OCT), and posterior segment OCT. IOL tilt and postoperative complications were assessed during follow-up.ResultsAt 12 months follow up all six IOLs were successfully repositioned intraoperatively. No complete IOL redislocation occurred during the available follow-up. Final BCVA was 0.14 ± 0.08 logMAR, and the mean IOL tilt was 2.43° ± 1.58°. A myopic refractive shift of 1.75 ± 0.22 D was observed compared with the pre-dislocation refraction. One eye (16.7%) developed partial inferior IOL subluxation, without associated visual or refractive deterioration, and two eyes (33.3%) developed cystoid macular edema, resolved with treatment.ConclusionIn this small proof-of-concept series, the double-rectangle 10-0 prolene suture technique allowed repositioning of dislocated rigid C-loop PMMA IOLs while avoiding a large corneal incision and was associated with favorable short-term anatomical outcomes. The occurrence of CME and partial IOL subluxation highlights the need for careful postoperative monitoring. Larger studies with longer follow-up are required to determine the long-term stability, safety, and reproducibility of the technique.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Late Reposition of a Dislocated Toric Intraocular Lens in a Fibrosed Capsular Bag: A Case Report.Case reports in ophthalmology · 2026
- Clinical outcomes of repositioning subluxated in-the-bag intraocular lenses using the flanged belt-loop technique with 6-0 polypropyleneJournal of Cataract & Refractive Surgery · 2025
- A new technique for correcting intraocular lens tilt after the Yamane technique.BMC ophthalmology · 2026
- A Novel Intraocular Lens and Capsular Bag Complex Suspension Technique for Repositioning Late In-the-Bag Intraocular Lens Dislocation.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Novel Ab Externo Rescue Technique of a Dislocated Four-point Scleral-Fixated Intraocular Lens.Retinal cases & brief reports · 2026
- Extraocularly Manipulated Flangeless Intrascleral Haptic Fixation of Intraocular Lens Using Zigzag Needles.Cureus · 2026