European journal of ophthalmology

Repositioning dislocated rigid C- loop intraocular lens using double rectangle prolene 10-0 sutures: A novel technique.

Pietro Maria Talli, Antonio Cartabellotta, Francesco Nasini, Sami Al-Nawaiseh, Jacopo Dell'Uomo, Laura Sarti, Ginevra Giovanna Adamo, Marco Pellegrini,

U.O. Oculistica, Azienda Ospedaliero, Universitaria di Ferrara, Ferrara, Italy. · Department of Translational Medicine, University of Ferrara, Ferrara, Italy.

Key points

From the paper's conclusion
  • One eye (16.7%) developed partial inferior IOL subluxation, without associated visual or refractive deterioration, and two eyes (33.3%) developed cystoid macular edema, resolved with treatment.ConclusionIn this small proof-of-concept series, the double-rectangle 10-0 prolene suture technique allowed repositioning of dislocated rigid C-loop PMMA IOLs while avoiding a large corneal incision and was

Abstract

PurposeTo describe a novel technique for repositioning dislocated rigid C-loop polymethyl methacrylate (PMMA) intraocular lenses (IOLs) without eyelets using a double-rectangle 10-0 prolene suture configuration.MethodsThis retrospective observational study included six eyes of patients with dislocated rigid C-loop PMMA IOLs in the vitreous cavity. All eyes underwent pars plana vitrectomy and repositioning of the existing IOL using a double-rectangle 10-0 prolene suture configuration, securing the IOL between the suture and the iris. Postoperative evaluation included best-corrected visual acuity (BCVA), slit-lamp biomicroscopy, fundoscopy, anterior segment optical coherence tomography (AS-OCT), and posterior segment OCT. IOL tilt and postoperative complications were assessed during follow-up.ResultsAt 12 months follow up all six IOLs were successfully repositioned intraoperatively. No complete IOL redislocation occurred during the available follow-up. Final BCVA was 0.14 ± 0.08 logMAR, and the mean IOL tilt was 2.43° ± 1.58°. A myopic refractive shift of 1.75 ± 0.22 D was observed compared with the pre-dislocation refraction. One eye (16.7%) developed partial inferior IOL subluxation, without associated visual or refractive deterioration, and two eyes (33.3%) developed cystoid macular edema, resolved with treatment.ConclusionIn this small proof-of-concept series, the double-rectangle 10-0 prolene suture technique allowed repositioning of dislocated rigid C-loop PMMA IOLs while avoiding a large corneal incision and was associated with favorable short-term anatomical outcomes. The occurrence of CME and partial IOL subluxation highlights the need for careful postoperative monitoring. Larger studies with longer follow-up are required to determine the long-term stability, safety, and reproducibility of the technique.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Repositioning dislocated rigid C- loop intraocular lens using double rectangle prolene 10-0 sutures: A novel technique — Science Skim