EXPRESS: Development of an ultrasound-guided pericapsular knee desensitization technique in cats: an anatomical cadaveric study.
Domineque Lemaitre, Pamela Mejías, María Belén Vásquez, Diego Arredondo, Marta Garbin, Diego A Portela, Pablo E Otero
Escuela de Medicina Veterinaria, Facultad Ciencias de la Vida, Universidad Andres Bello, Santiago, Chile. · Department of Clinical Science, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, QC, Canada.
Key points
From the paper's conclusion- Overall success was 23/24 injections (95.8%; 95% CI 78.9-99.9%) in the LV group and 21/24 (87.5%; 95% CI 67.6-97.3%) in the HV group.
Abstract
ObjectivesTo develop an ultrasound-guided pericapsular knee desensitization (PKD) technique targeting the medial (MAN), lateral (LAN) and posterior (PAN) articular branches of the saphenous, common fibular and tibial nerves, and to evaluate its accuracy in domestic feline cadavers.MethodsIn Phase I, six pelvic limbs from three cadavers underwent ultrasonographic evaluation and gross dissection to describe the course of the MAN, LAN and PAN and identify anatomical and sonographic landmarks for PKD. In Phase II, bilateral PKD was performed in eight cadavers (16 limbs) using 0.1 ml (low-volume, LV) or 0.2 ml (high-volume, HV) of dye per nerve, with volumes randomly assigned between limbs. MAN and PAN injections were performed under ultrasound guidance through a single medial percutaneous approach, whereas LAN injections were landmark-guided. Dissection was used to assess dye distribution around target nerves, the joint capsule and parent nerves.ResultsThe MAN was consistently located within the distal subsartorial canal alongside the descending genicular vessels, the PAN coursed adjacent to the popliteal vessels, and the LAN ran superficially near the fibular head and lateral head of the gastrocnemius muscle. Overall success was 23/24 injections (95.8%; 95% CI 78.9-99.9%) in the LV group and 21/24 (87.5%; 95% CI 67.6-97.3%) in the HV group. Both volumes stained the MAN, LAN and PAN trajectories and the medial, caudal and lateral surfaces of the knee joint capsule without intracapsular injection.Conclusions and relevanceUltrasound-guided PKD is feasible in domestic feline cadavers, and small injection volumes (0.1-0.2 ml per nerve) reliably reach pericapsular compartments containing the principal articular branches while largely sparing major motor nerves. These findings provide an anatomical and technical basis for future clinical evaluation of PKD for perioperative and chronic knee pain management in cats.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ventral approach for ultrasound-guided perineural injection of the canine L7 spinal nerve: a cadaveric feasibility study.Frontiers in veterinary science · 2026
- Genicular nerves: ultrasound anatomy, scanning techniques, and clinical implications.Journal of ultrasonography · 2026
- Improving Femoral Tunnel Placement in Canine Cranial Cruciate Ligament Reconstruction Using a Novel Adjustable Aiming Device: Evaluation Through Simulated Surgical Trials.Animals : an open access journal from MDPI · 2026
- Comparison of Ultrasonographic, Radiographic, Computed Tomographic, and Ex Vivo Measurements of Feline Femoral Trochlear Groove Depth.Animals : an open access journal from MDPI · 2026
- Simplified ultrasound-guided technique improves accuracy of median nerve perineural injection compared to "blind" techniques in equine ex vivo specimens.American journal of veterinary research · 2026
- Modified ultrasound-guided transversus thoracic plane block: cadaveric study and preliminary clinical results in dogs undergoing median sternotomy for thoracic surgeryFrontiers in Veterinary Science · 2026