Improving Femoral Tunnel Placement in Canine Cranial Cruciate Ligament Reconstruction Using a Novel Adjustable Aiming Device: Evaluation Through Simulated Surgical Trials.
Tsai-Yu Lee, Cheng-Chung Lin, Shih-Yuan Yang, Yu-Chih Wang, Ching-Ho Wu
Department of Surgery, National Taiwan University Veterinary Hospital, Taipei 10617, Taiwan. · Department of Electrical Engineering, Fu Jen Catholic University, New Taipei 242062, Taiwan.
Key points
From the paper's conclusion- These findings support improved positioning accuracy and consistency with the device in simulated canine CrCL reconstruction.
Abstract
Accurate femoral tunnel placement in canine cranial cruciate ligament (CrCL) reconstruction is challenging because of small joint anatomy and limited dedicated instrumentation. This study evaluated an adjustable femoral tunnel aiming device combined with patient-specific preoperative planning. Thirteen surgeons (six experienced and seven novices) performed simulated tunnel positioning using the device and a freehand technique. Outcomes included aperture positional error, measured as Euclidean distance (ED), angular deviation (AD), positioning time, and intra- and intersurgeon variability. Device-guided positioning reduced EDs (4.1-4.7 mm vs. 5.1-6.2 mm; p = 0.0275) and ADs (6.4-8.2° vs. 10.7-12.6°; p = 0.0038). Neither surgeon experience nor its interaction with technique significantly affected EDs or ADs. The device significantly reduced intrasurgeon variability in both outcomes and intersurgeon ADs variability among experienced surgeons. However, systematic distal bias (3.1-3.4 mm; p < 0.001) was observed with device-guided positioning. These findings support improved positioning accuracy and consistency with the device in simulated canine CrCL reconstruction. Further device refinement and hands-on practice may help address systematic deviations, while additional cadaveric and clinical validation is required before clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Image based three-dimensional kinematic mapping to optimize femoral tunnel placement for intra-articular cranial cruciate ligament reconstruction in dogs.Frontiers in veterinary science · 2026
- Kinematic Alignment Using Conventional Mechanical-Alignment Instruments with 3D-Printed Tibial Recut Guide Versus Manual Mechanical Alignment in Total Knee Arthroplasty: An IPTW-Adjusted Comparative Cohort Study.Journal of clinical medicine · 2026
- Three-dimensional ultrasonographic assessment of the cranial cruciate ligament in medium- to large-sized canine cadavers: a feasibility study.Veterinary journal (London, England : 1997) · 2026
- Improved precision and Reduced Technical Errors in Total Knee Arthroplasty Using the Velys Robotic-Assisted Solution: Single-Center Comparative Study.Acta orthopaedica Belgica · 2026
- Feasibility of an adjustable-angle arthroscope during ACL femoral tunnel creation: an ex vivo porcine knee study.Frontiers in surgery · 2026
- Cranial Cruciate Ligament Disease for the Small Animal Practitioner.The Veterinary clinics of North America. Small animal practice · 2026