Environmental contamination with fluorouracil on floors and ceilings in antineoplastic drug preparation and nonpreparation areas of a Japanese cancer center.
Koh Yoshida, Akimitsu Maeda, Kyoko Asano, Naoya Tomiyasu, Yumi Iida, Chiyoko Takahata, Kosaku Uchida
Department of Pharmacy, Aichi Cancer Center Hospital, Nagoya, Japan. · Department of Pharmacy, Aichi Children's Health and Medical Center, Obu, Japan.
Key points
From the paper's conclusion- These findings suggest that contamination may spread through the movement of healthcare workers and materials and may accumulate on infrequently cleaned surfaces.
Abstract
IntroductionEnvironmental monitoring of antineoplastic drug contamination has primarily focused on medication preparation areas and frequently touched surfaces. Consequently, contamination in nonpreparation areas and on infrequently touched surfaces, such as ceilings, remains poorly characterized. This study evaluated fluorouracil contamination on floors and ceilings in preparation and nonpreparation areas.MethodsThis study was conducted at Aichi Cancer Center, Japan. Samples were collected from floor and ceiling surfaces in the hospital pharmacy, outpatient chemotherapy center, and inpatient ward. Cleaning practices at the sampling sites were also assessed. Fluorouracil concentrations were measured using liquid chromatography-tandem mass spectrometry. At the time of sampling, closed-system drug-transfer devices (CSTDs) were not used for fluorouracil preparation or administration.ResultsFluorouracil was detected on all sampled floor and ceiling surfaces, including those in nonpreparation areas where antineoplastic drugs were not handled. The highest contamination levels were detected on the preparation room floor (3.104 ng/cm2) and the pharmacy break room ceiling (2.440 ng/cm2). In the outpatient chemotherapy center, relatively high contamination levels were detected on the nursing station floor (0.622 ng/cm2) and nursing break room ceiling (0.419 ng/cm2).ConclusionsFluorouracil contamination was detected in nonpreparation areas and on ceiling surfaces near air-conditioning units that were not routinely touched or cleaned. These findings suggest that contamination may spread through the movement of healthcare workers and materials and may accumulate on infrequently cleaned surfaces. As part of contamination control, the use of CSTDs may need to be implemented and environmental monitoring may need to be extended beyond medication preparation areas.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Closed-System Transfer Devices in Reducing Surface Contamination With Antineoplastic Drugs in Two Patient Administration Areas.Clinical journal of oncology nursing · 2026
- How safe is occupational exposure to citostatic drugs? Results from environmental and biological monitoring.Farmacia hospitalaria : organo oficial de expresion cientifica de la Sociedad Espanola de Farmacia Hospitalaria · 2026
- Assessing Surface Contamination by Hazardous Drugs in a Comprehensive Cancer Centre in Ireland Using Surface Wipe Sampling.Seminars in oncology nursing · 2026
- Compromised flushing fluid neutrality during sequential chemotherapy administration: an observational study.British journal of nursing (Mark Allen Publishing) · 2026
- Microbial contamination and infection control measures: experience of a medical complexJournal of Umm Al-Qura University for Medical Sciences · 2026
- Healthcare textile contamination along the post-laundering pathway: a multicentre study across a hospital network.The Journal of hospital infection · 2026