Healthcare textile contamination along the post-laundering pathway: a multicentre study across a hospital network.
C Duret, S Chevalier, J P Dernoncourt, D Poupon, A Saumet, B Aublanc, D Mameri-Gaget, A-S Jarreau,
Centre hospitalier de l'agglomération de Nevers, Unité départementale d'hygiène hospitalière, France; Centre hospitalier de Château-Chinon, Unité d'hygiène hospitalière, France; Centre hospitalier de Cosne sur Loire, Unité d'hygiène hospitalière, France. Electronic address: Duret.c01@ght58.fr. · Centre hospitalier de l'agglomération de Nevers, Unité départementale d'hygiène hospitalière, France.
Key points
From the paper's conclusion- Contamination patterns were consistent with exposure after laundering; site-specific profiles identified priorities for further investigation. Routine monitoring at laundry exit alone cannot identify where subsequent contamination occurs. Sampling successive stages of the clean-linen pathway may help identify potential recontamination points, guide targeted improvements and complement existing RABC programmes.
Abstract
BACKGROUND: Healthcare textiles are recognised as potential reservoirs of microorganisms, yet contamination along the post-laundering pathway remains insufficiently characterised. AIM: To assess microbiological contamination of healthcare textiles across a regional hospital network and identify sampling points with elevated contamination along the clean linen pathway. METHODS: This multicentre observational study included nine healthcare-facility groups comprising 17 geographically distinct sampling sites. Paired microbiological samples from external and internal surfaces of clean textiles were collected at upstream reference points, ward storage (cabinets or shelves) and nursing carts using contact plates. Paired counts and proportions exceeding 12 CFU were compared using two-sided Wilcoxon signed-rank and exact two-sided McNemar tests, respectively. Storage and textile-type associations were assessed using negative-binomial models adjusted for site, storage location and textile type, with sampling-batch-clustered robust standard errors. FINDINGS: Of 784 ward textiles sampled, 774 had complete paired results (1,548 contact samples); 331 pairs (662 samples) were analysed at reference points. At ward level, external counts exceeded internal counts (median 5 [1-14] vs 0 [0-1] CFU; Wilcoxon p<0.001). The 12-CFU threshold was exceeded by 210/774 external (27.1%) versus 41/774 internal samples (5.3%; McNemar p<0.001). Contamination profiles varied markedly among sites. No clear association was detected between storage location and external counts (ward storage areas vs nursing carts: IRR 1.01, 95% CI 0.75-1.36; p=0.930). The estimate for internal counts was lower in ward storage areas, but remained inconclusive (IRR 0.62, 95% CI 0.37-1.02; p=0.060). External and internal CFU counts differed significantly across textile types after adjustment for site and storage location (external: F[7,110]=3.46, p=0.002; internal: F[7,110]=12.02, p<0.001). CONCLUSION: Contamination patterns were consistent with exposure after laundering; site-specific profiles identified priorities for further investigation. Routine monitoring at laundry exit alone cannot identify where subsequent contamination occurs. Sampling successive stages of the clean-linen pathway may help identify potential recontamination points, guide targeted improvements and complement existing RABC programmes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contamination of reusable cleaning tools in healthcare settings: a study based on the longitudinal surveillance in Shanghai.Frontiers in public health · 2026
- Bacterial Contamination of Paper-Towel Dispensers in Healthcare Settings: A Cross-Sectional Environmental Surveillance Study.The Journal of hospital infection · 2026
- Characterising the Hospital Microbiota: A Descriptive Study of Environmental Monitoring.Pathogens (Basel, Switzerland) · 2026
- Assessing Surface Contamination by Hazardous Drugs in a Comprehensive Cancer Centre in Ireland Using Surface Wipe Sampling.Seminars in oncology nursing · 2026
- Assessment of microbial contamination of mobile phones among medical staff, students, and visitors in a pediatric hematology-oncology ward and its relationship with infections among pediatric patients.Archives of medical science : AMS · 2026
- Microbial contamination and infection control measures: experience of a medical complexJournal of Umm Al-Qura University for Medical Sciences · 2026