Validation of a Low-Cost Surgical Simulation Model for Cleft Lip Repair Training: A Multicentre Trainer-Trainee Workshop Study.
Madhubari Vathulya, Smruti Srinivasan, Hemanth Kumar K, Deviprasad Mohapatra, Konstanze Scheller, Peter Kessler
Department of Burns and Plastic Surgery, All India Institute of Medical Sciences (AIIMS) Rishikesh, Rishikesh UK, India. · Department of Plastic & Reconstructive Surgery, Himalayan Institute of Medical Sciences, Dehradun, UK, India.
Key points
From the paper's conclusion- ObjectiveTo evaluate the face, content and construct validity of a low-cost unilateral cleft lip trainer through a multicentre trainee-trainer workshop.DesignProspective multicentre validation study.SettingThree accredited plastic surgery training centres.Patients/ParticipantsSixty-two plastic surgery residents participated in standardised simulation workshops.InterventionsParticipants underwent l
Abstract
ObjectiveTo evaluate the face, content and construct validity of a low-cost unilateral cleft lip trainer through a multicentre trainee-trainer workshop.DesignProspective multicentre validation study.SettingThree accredited plastic surgery training centres.Patients/ParticipantsSixty-two plastic surgery residents participated in standardised simulation workshops.InterventionsParticipants underwent lectures, video demonstrations and supervised practice of unilateral cleft lip repair using the low-cost simulator. Pre- and post-workshop questionnaires assessed self-reported knowledge and procedural understanding. Participants rated the model for face and content validity using a 5-point Likert scale. Faculty assessed simulator-based performance using a 10-point checklist.Main Outcome Measure(s)Face validity, content validity, construct validity, pre- and post-workshop knowledge scores, repair time, suture-line integrity and lip-height symmetry.ResultsKnowledge scores increased from 55% to 87%, with significant improvement in chronological recall of repair steps (P < .001). Face validity exceeded 90% across anatomical and procedural domains, with teaching usefulness rated highest (98%). Content validity was strongly supported, with 99% of participants recommending curriculum integration. Construct validity demonstrated significant discrimination between first-, second- and third-year residents, with mean performance scores of 7.1, 8.4 and 9.6, respectively (P < .001). Repair times decreased with increasing training level, while senior trainees achieved superior repair quality.ConclusionsThe low-cost unilateral cleft lip trainer demonstrated favourable face, content and construct validity within a structured workshop setting. Its affordability and reproducibility support its use as an adjunct for procedural rehearsal and assessment in plastic surgery training.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simulation-Based Training Tools for Cleft Lip Repair: A Systematic Review.Journal of clinical medicine · 2026
- Comparison Between the Likert Scale and the Visual Analog Scale for the 3D Esthetic Assessment of Primary Cleft Lip Repair: A Prospective Study.International journal of dentistry · 2026
- Evaluation of Low-Cost Smiley Graded-Zone Simulator for Endoscopic Endonasal Dural Suturing Training.The Laryngoscope · 2026
- A low cost silicone mandibular model for suturing skills training among undergraduate medical students: development and comparative evaluation.BMC medical education · 2026
- Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training modelArchives of Gynecology and Obstetrics · 2026
- Low-Cost Vegetal Simulation for Ear Reconstruction (Otopoiesis) Training: A Technical Report.Cureus · 2026