Evaluation of Low-Cost Smiley Graded-Zone Simulator for Endoscopic Endonasal Dural Suturing Training.
Ashwin Gajendran Vedhapoodi, Yudo Ishii, Vivek Mariappan, Saravana Selvan Velmurugan, Vinod Felix, Kohei Ishikawa, Kazuhiro Omura, Venugopal Mohankumar,
Upgraded Institute of Otorhinolaryngology, Madras Medical College, Chennai, India. · Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.
Key points
From the paper's conclusion- The Smiley model is a low-cost, replicable tool for improving endoscopic endonasal dural suturing performance. It demonstrates construct and content validity, with partial face validity as preliminary evidence of validity, while focusing on a single psychomotor skill-endoscopic suturing-without anatomical fidelity.
Abstract
BACKGROUND: Endoscopic endonasal dural suturing is an evolving technique for achieving watertight reconstruction following Expanded Endoscopic Endonasal Approaches. This study evaluates a low-cost, replicable model for improving endoscopic endonasal dural suturing skills. METHODS: The Smiley model box trainer was designed for endoscopic endonasal dural suturing. Four participant groups (n = 33)-specialists, midlevel practitioners, beginners, and junior residents (two sessions)-performed four-handed endoscopic suturing using an external slip knot and internal loop knot across varying difficulty zones. Groups were compared using skill assessment scale scores and single-knot completion time. RESULTS: Specialists demonstrated significantly higher scores in hand-eye coordination, needle handling, external slip knot, internal loop knot, and total mean scores than beginners (16/20 vs. 10.75/20) and junior residents-first session (16/20 vs. 10.63/20). Specialists also required shorter task completion times than beginners (6.63 vs. 15.33 min) and junior residents-first session (6.63 vs. 15.75 min). Junior residents showed improved performance in their second session, conducted 1 week later. The Smiley model demonstrated construct validity and significant content validity (average = 0.875). Post-activity self-assessed proficiency scores improved in the midlevel (3.6/10 vs. 8/10), beginner (2.5/10 vs. 6.92/10), and junior resident first-session (2.5/10 vs. 7.13/10) groups, with statistically significant improvements in the latter two groups. CONCLUSION: The Smiley model is a low-cost, replicable tool for improving endoscopic endonasal dural suturing performance. It demonstrates construct and content validity, with partial face validity as preliminary evidence of validity, while focusing on a single psychomotor skill-endoscopic suturing-without anatomical fidelity. LEVEL OF EVIDENCE: NA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and validation of a Dor fundoplication simulator.JTCVS open · 2026
- A low cost silicone mandibular model for suturing skills training among undergraduate medical students: development and comparative evaluation.BMC medical education · 2026
- Validation of a Low-Cost Surgical Simulation Model for Cleft Lip Repair Training: A Multicentre Trainer-Trainee Workshop Study.The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association · 2026
- A Task-Specific Performance Rating Scale for Laparoscopic Intracorporeal Suturing and Knot Tying: Development and Initial Evaluation.Journal of laparoendoscopic & advanced surgical techniques. Part A · 2026
- Multimodal Large Language Models Rate Wetlab Suturing Repeatably but Fail to Detect Training-Related Improvement: A Pilot Study With Expert Assessment.Cureus · 2026
- A Novel ex vivo Snare Tip Soft Coagulation Model for Deliberate Self-Practice and Assessing Endoscopic Tip-Control Competency: The HAM-2 Study.Endoscopy international open · 2026