Dual mini-plate versus mini-plus-standard plate fixation for displaced medial clavicle fractures: A retrospective comparative study.
Xiaowen Huang, Tianrun Lü, Jiuxiang Liu
Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University (Jiangsu Provincial People's Hospital), Nanjing, Jiangsu, China.
Key points
From the paper's conclusion- ObjectiveTo compare clinical and perioperative outcomes of dual mini-plate fixation with mini-plus-standard plate fixation for displaced medial clavicle fractures.MethodsWe retrospectively reviewed 30 patients treated surgically between October 2016 and March 2023.
Abstract
ObjectiveTo compare clinical and perioperative outcomes of dual mini-plate fixation with mini-plus-standard plate fixation for displaced medial clavicle fractures.MethodsWe retrospectively reviewed 30 patients treated surgically between October 2016 and March 2023. Group A (n=16) underwent dual mini-plate fixation using two 2.7-mm low-profile plates, whereas Group B (n=14) underwent mini-plus-standard plate fixation using a contoured inverted distal clavicle locking plate together with a 2.7-mm mini-plate. Operative time, blood loss, a study-specific intraoperative construct-stability assessment, fracture healing, implant-related complications, Constant-Murley score, Rockwood score, and Disabilities of the Arm, Shoulder, and Hand (DASH) score were compared.ResultsOperative time was shorter with dual mini-plate fixation (48.8±11.8 vs. 59.5±13.7 min; P=0.029), and stable fixation on the intraoperative assessment was more frequent (15/16 [93.8%] vs. 8/14 [57.1%]; Fisher exact P=0.031). Blood loss and radiographic healing time were similar between groups. Implant-related skin irritation with persistent local discomfort occurred in 0/16 patients in Group A and 6/14 (42.9%) in Group B (P=0.005); symptoms improved after hardware removal. Constant-Murley and Rockwood scores were comparable, whereas the final DASH score was lower in Group A (1.6±0.3 vs. 2.1±0.4; P<0.001).ConclusionBoth constructs achieved fracture union and good shoulder function in this small retrospective series. Dual mini-plate fixation was associated with shorter operative time, greater intraoperative construct stability, and less implant prominence-related irritation than the mini-plus-standard plate construct. These findings should be interpreted in view of the nonrandomized design and limited sample size.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative effectiveness of one versus two miniplates in the management of mandibular angle fractures: a systematic review and meta-analysis.The British journal of oral & maxillofacial surgery · 2026
- Plate Fixation with and without Suture Endobutton Augmentation of the CoracoClavicular Ligament in displaced Lateral Clavicle Fractures: A Comparative Outcome Study.Journal of orthopaedic trauma · 2026
- Mini-open intramedullary fixation with attempted supraclavicular nerve preservation versus plate fixation for midshaft clavicle fractures: A retrospective comparative study.Journal of orthopaedic surgery (Hong Kong) · 2026
- Clinical Efficacy Comparison of Bilaterally Threaded Elastic Locking Intramedullary Nailing Versus Minimally Invasive Percutaneous Locking Plate Fixation in Treating Midshaft Clavicle Fractures.Annali italiani di chirurgia · 2026
- Superior compared with anteroinferior plating for mid-shaft fractures of the clavicleThe Bone & Joint Journal · 2026
- Locking plate fixation with coracoclavicular augmentation through cannulated locking screws for unstable distal clavicle fractures: A retrospective case series.Journal of orthopaedic surgery (Hong Kong) · 2026