Locking plate fixation with coracoclavicular augmentation through cannulated locking screws for unstable distal clavicle fractures: A retrospective case series.
Ji Woong Kim, Da Jeong Pak, Sung Yoon Jung
Department of Orthopaedic Surgery, Dong-A University Hospital, Busan, South Korea.
Key points
From the paper's conclusion- PurposeTo describe a hybrid fixation technique combining a superior distal clavicle locking plate with coracoclavicular (CC) augmentation through cannulated locking screws and to report its radiological and clinical outcomes.MethodsWe retrospectively reviewed a consecutive surgical cohort treated between March 2022 and March 2025.
Abstract
PurposeTo describe a hybrid fixation technique combining a superior distal clavicle locking plate with coracoclavicular (CC) augmentation through cannulated locking screws and to report its radiological and clinical outcomes.MethodsWe retrospectively reviewed a consecutive surgical cohort treated between March 2022 and March 2025. Of 26 patients who underwent the procedure, 4 were excluded because of follow-up of less than 12 months or loss to follow-up, leaving 22 patients for analysis. Two 2.4-mm × 8.5-mm suture anchors were placed at the conoid and trapezoid footprints of the coracoid base, and the sutures were shuttled from the anteroinferior aspect of the clavicle through cannulated locking screw lumens. Outcomes included union, maintenance of reduction, complications, pain, function, and shoulder motion.ResultsAll 22 fractures united at a mean of 12.8 ± 2.5 weeks. The final CC distance ratio was 1.05 ± 0.10. The mean visual analogue scale and QuickDASH scores were 0.6 ± 0.8 and 5.4 ± 2.1, respectively. No coracoid cortical breach, neurovascular injury, implant failure, loss of reduction, or implant removal occurred. Three patients developed transient supraclavicular nerve irritation, which resolved spontaneously.ConclusionThis technique provided reliable union, maintained reduction, and favorable short-term clinical outcomes. It may provide an anatomically oriented option for supplementary CC stabilization, although comparative and biomechanical studies are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Augmented Fixation of Distal Clavicle Fractures: High Union, Moderate Complications.Cureus · 2026
- Plate Fixation with and without Suture Endobutton Augmentation of the CoracoClavicular Ligament in displaced Lateral Clavicle Fractures: A Comparative Outcome Study.Journal of orthopaedic trauma · 2026
- Anatomical Conoid Ligament Reconstruction Improves Posterior Stability in Neer Type IIB Distal Clavicle Fractures: A Cadaveric Biomechanical Study.Journal of shoulder and elbow surgery · 2026
- Superior compared with anteroinferior plating for mid-shaft fractures of the clavicleThe Bone & Joint Journal · 2026
- Dual mini-plate versus mini-plus-standard plate fixation for displaced medial clavicle fractures: A retrospective comparative study.Journal of orthopaedic surgery (Hong Kong) · 2026
- Soft Cerclage in Addition to Rigid Fixation for Surgical Management of Displaced Comminuted Midshaft Clavicle FracturesArthroscopy Techniques · 2026