Patient-specific biomechanical evaluation of vertical TMJ splints in class II malocclusion with disc displacement: Influence of splint thickness and muscle fibre orientation.
Ananta Jain, Rashmi Uddanwadikar, Sunita Shrivastav, Ananya Hazare, Manika Jaiswal
Department of Mechanical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India. · Ranjeet Deshmukh Dental College and Research Centre, Nagpur, India.
Key points
From the paper's conclusion- Among the investigated configurations, the 5 mm splint in the mild disc displacement model (≈81% reduction) and the 4 mm splint in the moderate disc displacement model (≈83.7% reduction) demonstrated the most favourable biomechanical responses under the prescribed loading conditions.
Abstract
This study aims to elucidate morphology-specific temporomandibular joint (TMJ) biomechanical responses to vertical splints of varying thickness in Class II malocclusion with anterior disc displacement using a subject-specific finite element framework and to investigate the mechanistic basis of splint-induced load redistribution. MRI- and CBCT-derived finite element models were developed for two representative Class II malocclusion subjects with mild (20°-40°) and moderate (40°-60°) anterior disc displacement. Articular disc was modelled using a nonlinear hyperelastic formulation, and muscle forces were applied from validated literature with subject-specific orientations. Vertical splints (1-5 mm) and horizontal splints were simulated under physiologically relevant muscle-driven loading. Peak von Mises stress, Stress Concentration Index (SCI), and Peak Stress Mitigation Degree (PSMD) were evaluated. Baseline peak disc stress reached 22.34 MPa (mild) and 38.283 MPa (moderate). Vertical splints produced progressive stress reduction, with dominant unloading up to 3-4 mm followed by a plateau or rebound. Among the investigated configurations, the 5 mm splint in the mild disc displacement model (≈81% reduction) and the 4 mm splint in the moderate disc displacement model (≈83.7% reduction) demonstrated the most favourable biomechanical responses under the prescribed loading conditions. SCI decreased and PSMD increased with thickness, indicating improved load distribution. Horizontal splints demonstrated limited biomechanical benefit. TMJ biomechanical response to splint therapy is morphology- and severity-dependent, exhibiting nonlinear thickness effects and warranting validation in larger longitudinal cohorts. Vertical splint thickness influences temporomandibular joint stress distribution in a morphology-dependent manner. The subject-specific computational findings, supported by corresponding 3-month clinical and MRI findings, provide a biomechanical basis for further investigation of morphology-specific, thickness-optimized splint design in the conservative management of temporomandibular disorders.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of occlusal splint design and thickness on temporomandibular joint loading: a finite element studyBMC Oral Health · 2026
- Protrusive mandibular kinematics in anterior disc displacement: a CT-based 3D motion analysis before and after occlusal splint therapy.Journal of biomechanics · 2026
- An exploratory patient-specific finite element study of temporomandibular joint stress distribution following mandibular setback surgery in two distinct clinical scenarios.BMC oral health · 2026
- Biomechanical Evaluation of the Temporomandibular Joint Following Multi-Directional Orthognathic Surgery: A Finite Element Analysis.Medical engineering & physics · 2026
- Effects of Anterior Repositioning Splint on Temporomandibular Joint Positional and Morphological Parameters and Facial Symmetry in Patients With Temporomandibular Disorders and Functional Mandibular Deviation: A Prospective Study.Journal of oral rehabilitation · 2026
- Effect of the Occlusal Splint Therapy on Mandibular Condylar Position in Patients With Myofascial Pain and an Average Skeletal Growth Pattern: A CBCT-Based Randomized Controlled Trial.Cureus · 2026