Technology and health care : official journal of the European Society for Engineering and Medicine

Effects of localized vibration training on the strength of the biceps brachii muscle and hand grip: A randomized comparative trial.

Ahmad H Alghadir, Zaheen Ahmed Iqbal, Talal Alghadir, Faisal Alghadir, Amir Iqbal

Department of Rehabilitation Health Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.

Randomised

Key points

From the paper's conclusion
  • Effect sizes from baseline to 20minutes were small for biceps brachii strength (42 Hz: d = 0.19; 63 Hz: d = 0.17) and hand grip strength (42 Hz: d = 0.12; 63 Hz: d = 0.02).ConclusionsLocalized vibration at 42 Hz and 63 Hz produced comparable acute effects on biceps brachii isometric and hand grip strength.

Abstract

BackgroundAcute vibration exercise may enhance muscle force; however, the optimal vibration frequency for maximizing acute strength remains uncertain.ObjectiveTo compare the acute effects of localized vibration at 42 Hz and 63 Hz on biceps brachii isometric and hand grip strength in healthy males.MethodsThirty healthy males (20-50 years) were randomly allocated to receive five 1-min bouts of localized biceps brachii vibration at either 42 Hz or 63 Hz, separated by 1-min rest intervals. Isometric biceps and hand grip strength were assessed at baseline, immediately after intervention, and 10 and 20 min post-intervention.ResultsNo significant within-group changes in either outcome were observed after 42 Hz vibration (p > 0.05), whereas 63 Hz vibration produced significant within-group reductions over time (p < 0.05). However, the primary between-group comparisons showed no significant differences at any time point (p > 0.05). Effect sizes from baseline to 20minutes were small for biceps brachii strength (42 Hz: d = 0.19; 63 Hz: d = 0.17) and hand grip strength (42 Hz: d = 0.12; 63 Hz: d = 0.02).ConclusionsLocalized vibration at 42 Hz and 63 Hz produced comparable acute effects on biceps brachii isometric and hand grip strength. Although strength was relatively preserved after 42 Hz and showed small within-group reductions after 63 Hz, these findings should be interpreted cautiously because of retrospective trial registration, the absence of a non-vibration control group, unmeasured vibration amplitude, and the modest sample size, which may have limited the detection of small between-group differences.Trial registrationThe study was retrospectively registered in ClinicalTrials.gov under identifier NCT05523232 on 31/08/2022 after completion of data collection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers