Outcomes of Single-View Asymmetries Recalled From Screening Mammography and Exploratory Analysis of AI Detection.
Huijuan Wang, Shrouq Solimanie, Fatma Eldehimi, Amit Katyan, Jean M Seely
University of Ottawa, ON, Canada.
Key points
From the paper's conclusion- SVAs were a common but very low-yield cause of recall in screening mammography. Although exploratory, the low malignancy yield among non-AI-flagged SVAs suggests a potential role for AI as a supportive adjunct in risk stratification and recall decision-making.
Abstract
PURPOSE: To evaluate the diagnostic outcomes of single-view asymmetries (SVAs) recalled from screening mammography and to explore the association between artificial intelligence (AI) detection and malignancy. METHODS: This REB-approved retrospective single-center study included women recalled for SVAs from screening mammography performed at The Ottawa Hospital between March 1, 2024 and March 31, 2025. SVAs were defined as asymmetries identified on a single mammographic projection. Screening performance metrics were obtained from the EPIC Mammography Quality Standards Act module, and imaging outcomes were reviewed in PACS. Primary outcomes included cancer detection rate (CDR), positive predictive value for recall (PPV1), and positive predictive value for biopsy (PPV3). Following implementation of AI software (Transpara) in September/October 2024, exploratory analyses evaluated associations between AI flag status and malignancy. RESULTS: Among 32 412 screening examinations, 2455 patients (7.6%) were recalled, including 410 patients with 464 SVAs. Five cancers were identified, corresponding to a CDR of 0.16 per 1000 screened patients, significantly lower than the overall screening CDR of 6.08 per 1000 (P < .0001). PPV1 for SVAs was 1.22% (5/410), significantly lower than the overall PPV1 of 8.02% (197/2455) (P < .0001). Twenty-five patients (5.4%) underwent biopsy, yielding a PPV3 of 20%. Overall, 98.8% of recalled SVAs were non-malignant. Following AI implementation, malignancy rates were 0.6% (1/154) among non-flagged SVAs and 2.9% (2/68) among AI-flagged SVAs (P = .17). All malignancies were Stage I at diagnosis. CONCLUSION: SVAs were a common but very low-yield cause of recall in screening mammography. Although exploratory, the low malignancy yield among non-AI-flagged SVAs suggests a potential role for AI as a supportive adjunct in risk stratification and recall decision-making.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance of an Artificial Intelligence Support System on Screening Mammography Cases Proceeding to Stereotactic BiopsyCancers · 2025
- AI software as a third reader in breast cancer screening—a prospective diagnostic observational studyEuropean Radiology · 2026
- Artificial Intelligence as triage in breast screening: simulated impact on workload and detectionEuropean Journal of Public Health · 2026
- Real-world performance of a Food and Drug Administration-approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips.Radiology advances · 2026
- AI output and image quality: reducing avoidable recalls in breast screeningEuropean Journal of Public Health · 2026
- Over-detection and over-surveillance in breast screening: current status and the potential for artificial intelligence optimisationInsights into Imaging · 2025