Fire testing and failure mechanism of roof decking
Ankit Sharma, Evan Sluder, Ickchan Kim, Alexander B. Morgan, Mauro Zammarano
National Institute of Standards and Technology · Insurance Institute for Highway Safety
Abstract
This study investigated the fire performance of roofing materials under controlled laboratory conditions, with a focus on the ignition mechanisms of roof decking and their implications for fire testing and material flammability. Mockup roof assemblies, comprising asphalt shingles, underlayment, and wooden decking, were tested at both bench and large scales. Large-scale testing employed a modified version of the ASTM E108 Burning Brand test, the standard used to classify the fire performance of roof coverings. Bench-scale evaluation was conducted using a cone calorimeter equipped with a specialized sample holder adapted from ASTM E3367 and designed to accommodate multilayer assemblies. This configuration (commonly referred to as the Cube test) was intended to replicate fire exposure conditions similar to those in ASTM E108. In both test configurations, flaming beneath the roof decking occurred without any apparent perforation, that is, without the formation of breaks or fissures in the roof assembly. Video analysis of the tests revealed that ignition on the underside of the specimens was initiated by intense smoldering, which eventually transitioned into flaming. This ignition mechanism, known as the smoldering-to-flaming transition, represents a fundamentally different failure mode from burn-through, in which flames penetrate through openings in the structure. This study experimentally demonstrated and mechanistically explained this transition as a possible cause of the long-standing reproducibility issues in ASTM E108. Underside flaming occurred only when airflow increased oxygen supply, with air velocity controlling the transition through competing effects of enhanced char oxidation/pyrolysis and convective cooling. These findings emphasize the need for detailed airflow characterization beneath roofing test assemblies for a reproducible and reliable assessment of roof assemblies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Roof Coatings for Mitigating Fire Spread in Rooftop Photovoltaic AssembliesFire and Materials · 2026
- Analysis of the Fire Behavior of Building-Integrated Photovoltaics (BIPV) as Façade MaterialsApplied Sciences · 2025
- Response-Specific Thermal Equivalence of Full-Scale Multi-Material Fire-Door Systems Under Seven Fire Histories.Materials (Basel, Switzerland) · 2026
- Wind-Driven Building-to-Building Fire Spread: Experimental Results and Probabilistic ModelingFire Technology · 2026
- Fire Safety: Stage‐Dependent Fire Behavior, Performance Criteria, and Application‐Based RequirementSafety Science and Technology · 2026
- Experimental Evaluation of the Fire Performance of Pipe Insulation Materials Under ISO 20632 Actual Fire Test ConditionsFire · 2026