Clinical validation of continuous glucose monitoring in glycemic management of critically ill sepsis patients: A prospective randomized clinical study.
Qin Si, Yifeng Mao, Jian Lan, Wei Lu, Cheng Zheng, Qian Zhu, Xijiang Zhang
Department of Critical Care Medicine, Taizhou Municipal Hospital (Taizhou University Affiliated Municipal Hospital), School of Medicine, Taizhou University, China. · Nursing Department, Taizhou Municipal Hospital (Taizhou University Affiliated Municipal Hospital), School of Medicine, Taizhou University, China.
Key points
From the paper's conclusion- ObjectiveThis study assessed the accuracy, clinical effectiveness, and utility of continuous glucose monitoring compared with conventional methods in critically ill patients with sepsis.MethodsFrom July 2023 to July 2025, 60 patients with sepsis (mean age, 75.6 ± 27.107 years; mean body mass index, 22.4 ± 2.960 kg/m2) were randomized to the continuous glucose monitoring (FreeStyle Libre II system)
Abstract
ObjectiveThis study assessed the accuracy, clinical effectiveness, and utility of continuous glucose monitoring compared with conventional methods in critically ill patients with sepsis.MethodsFrom July 2023 to July 2025, 60 patients with sepsis (mean age, 75.6 ± 27.107 years; mean body mass index, 22.4 ± 2.960 kg/m2) were randomized to the continuous glucose monitoring (FreeStyle Libre II system) or conventional monitoring group in this prospective randomized trial. Conventional monitoring (self-monitoring of blood glucose using a glucometer with fingertip capillary samples, plus arterial/venous measurements) was applied in the control group, whereas the intervention group additionally received continuous glucose monitoring. Outcomes included glucose measurement results, protocol adherence, efficiency, and accuracy, assessed using correlation analysis, the Diabetes Technology Society error grid, and International Standardization Organization conformity.ResultsContinuous glucose monitoring demonstrated a high correlation (r = 0.986, p < 0.001), a low mean absolute relative deviation (11.44%), and 100% of readings fell within the clinically acceptable Zones A (91.9%) and B (8.1%) on the Diabetes Technology Society error grid analysis. The continuous glucose monitoring group showed significantly higher glycemic protocol adherence (73.91% vs. 48.16%, p < 0.001) and a shorter measurement time (41.33 vs. 63.67 s). Continuous glucose monitoring detected more hypoglycemic events (2.46% vs. 0.28%, p < 0.001) and fewer hyperglycemic events (44.38% vs. 50.88%, p < 0.001), with a higher time in the target range (33.23% vs. 26.26%).ConclusionsContinuous glucose monitoring is an accurate and clinically feasible method for real-time glucose monitoring in critically ill patients with sepsis in the intensive care unit. It enhances protocol adherence, improves dysglycemia detection, reduces nursing workload, and enables more precise insulin titration. Larger multicenter studies are warranted to confirm its long-term effects and cost-effectiveness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of Hybrid Continuous Glucose Monitoring on Glycemic Control in a Medical Intensive Care Unit.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2026
- Accuracy of an Interstitial Continuous Glucose Management System in Critically Ill Patients: A Prospective Observational Study.Journal of diabetes science and technology · 2026
- Association of continuous glucose monitoring with in-hospital adverse outcomes among critically ill patients: a real-world propensity score-matched study.Frontiers in endocrinology · 2026
- Continuous glucose monitoring for diabetes mellitus in the perioperative and intensive care setting: a prospective observational validation study✰.British journal of anaesthesia · 2026
- Comparing efficacy in glycaemic control and pregnancy outcomes between continuous glucose monitoring and self-monitoring of blood glucose in pregnancies complicated by gestational diabetes mellitus: a systematic review and meta-analysis.Diabetes research and clinical practice · 2026
- Determinants of Continuous Glucose Monitoring Accuracy in Critically Ill Patients Requiring Mechanical Ventilation and Vasopressor Support.Diabetes technology & therapeutics · 2026