Pressure - flow measurements of pumps used in extracorporeal life support.
Federico Rorro, Lisa Prahl Wittberg, Fabio Silvio Taccone, Nicholas A Barrett, Maximilain V Malfertheiner, Matteo Di Nardo, Justyna Swol, Jan Belohlavek,
FLOW, Department of Engineering Mechanics, Royal Institute of Technology (KTH), Stockholm, Sweden. · Department of Intensive Care, Hôpital Universitaire de Bruxelles (HUB), Université Libre de Bruxelles (ULB), Brussels, Belgium.
Key points
From the paper's conclusion- As agreed with manufacturers, no direct comparisons between pumps were made.ConclusionsPerformance curves for blood pumps designed for ECLS use in children and adults were reported and important aspects of design features discussed to support clinicians.
Abstract
IntroductionThe blood pump is a central component of the extracorporeal life support (ECLS) circuit. Modern centrifugal and diagonal pumps are mainly used in preference to roller pumps. Compared to roller pumps, centrifugal and diagonal pumps offer lower priming volume, less hemolysis and enable miniaturization of circuits. Drawback is the open design promoting internal recirculation, which influences performance and, in few studies at low flow, may increase risk of coagulation activation and hemolysis. The aim of this work was to provide performance data on available pumps.MethodsManufacturers were asked to lend ECLS consoles and donate pump samples for the study. No financial support was accepted. Missing pumps were bought by the investigators. In a mock-loop, measurements of volume flow and pressures were performed. Pumps were assessed over the operating flow range stated by the manufacturer at different preloads and afterload levels.ResultsEight different ECLS pumps were tested, two available for pediatric use and six for adult use. Six pumps were centrifugal and two were of diagonal design. All were magnetically driven and three were magnetically levitated. Five had impellers with shrouded (covered) design. Water or water-glucose were used as a test fluid and choice of medium is herewith also discussed. Flow-pressure maps for each pump were generated over its operating range. As agreed with manufacturers, no direct comparisons between pumps were made.ConclusionsPerformance curves for blood pumps designed for ECLS use in children and adults were reported and important aspects of design features discussed to support clinicians.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparing hemolysis among extracorporeal pumps: A large-scale retrospective study.Perfusion · 2026
- Pressure behavior in a roller pump-driven low-flow VACC mock circuit with inactive de-airing pump: A descriptive bench characterization under reduced patient-side effective filling pressure conditions.PloS one · 2026
- A Novel Extracorporeal Membrane Oxygenation System With Enhanced Hemocompatibility and Long-Term Stability.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Methodology for computational assessment of hemolysis in under-occlusive roller pumps operated at clinically relevant conditions.Bioengineering & translational medicine · 2026
- Challenges and opportunities in ECMO monitoring: A mixed-methods appraisal.The journal of extra-corporeal technology · 2026
- Reperfused human umbilical cords: hydrodynamic and hemolytic analysis of the ex vivo model for umbilical cord ECMO cannulation.Frontiers in bioengineering and biotechnology · 2026