Assessment of Respiratory Mechanics and Inspiratory Effort During Spontaneous Breathing Trials to Predict Extubation Failure in High-Risk Patients
Francesco Murgolo, Savino Spadaro, Domenico Luca Grieco, Michele Bertoni, Luigi Pisani, Giorgia Spinazzola, Rosa Di Mussi, Teresa Michi,
Azienda Universitaria Ospedaliera Consorziale - Policlinico Bari · University of Ferrara
Key points
From the paper's conclusion- Conclusions In high-risk patients, SBT-induced declines in respiratory system compliance and increases in inspiratory effort are associated with extubation failure.
Abstract
Abstract Rationale Conventional parameters to determine the success of spontaneous breathing trials (SBTs) may fail to detect impending respiratory distress. Objectives To assess whether SBT-induced changes in respiratory system compliance, inspiratory effort, and respiratory drive measured as occlusion pressure during the first 100 milliseconds (P0.1), all assessed noninvasively through airway occlusions, are associated with extubation outcomes. Methods We conducted a multicenter study on patients at high risk of extubation failure who successfully passed a 30-minute SBT on the basis of conventional parameters. The SBT was reproduced using a specific ventilator immediately before extubation to continuously monitor respiratory system compliance, inspiratory effort, and P0.1. Extubation failure was defined as reintubation within 72 hours. Measurements and Main Results Forty-six (19%) of 238 extubated patients required reintubation. No differences in Vt or respiratory rate were observed between successfully extubated and reintubated patients at any time. In the success group, inspiratory effort and normalized compliance (i.e., scaled to predicted body weight) remained unchanged throughout the SBT. In the failure group, normalized compliance declined (1.0 [0.8–1.2] to 0.7 [0.6–0.9] ml/cm H2O/kg; P < 0.001), whereas inspiratory effort increased (12 [10–15] to 18 [15–20] cm H2O; P < 0.001) during the SBT. P0.1 increased in both groups but more markedly in reintubated patients (2 [1.5–2.4] to 3.2 [2.9–3.5] cm H2O; P < 0.001). SBT-induced normalized compliance reduction less than or equal to −0.2 ml/cm H2O/kg (less than or equal to −0.1; less than or equal to −0.2) and inspiratory effort increase >2 cm H2O (>1, >3) were the most accurate predictors of extubation failure (area under the curve, 0.90 [0.84–0.93]; sensitivity, 80%; specificity, 83%; area under the curve, 0.94 [0.90–0.97]; sensitivity, 89%; specificity, 93%, respectively). Conclusions In high-risk patients, SBT-induced declines in respiratory system compliance and increases in inspiratory effort are associated with extubation failure. Clinical trial registered with www.clinicaltrials.gov (NCT05295186).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Flow Index Trajectories During Spontaneous Breathing Trials Are Associated With Extubation Failure: A Latent Class Trajectory Modeling Study.Clinical and translational science · 2026
- Integrated comprehensive assessment for predicting weaning success in difficult-to-wean critically ill patients: the WEAN-US studyCritical Care · 2026
- Negative inspiratory force predicts extubation failure after planned extubation in a medical ICU: a prospective cohort study.Intensive & critical care nursing · 2026
- Automated Versus Manual Occlusion Pressure at 100 ms With Hamilton C6 Using the Software Version 1.2.3: From Bedside to the Bench and Back to Bedside.Critical care explorations · 2026
- Which spontaneous breathing trial should be used to reproduce post-extubation respiratory effort in COVID-19-related ARDS? A multicenter randomized crossover study.Anaesthesia, critical care & pain medicine · 2026
- Electrical impedance tomography for predicting weaning failure from mechanical ventilation: a systematic review and meta-analysisFrontiers in Medicine · 2026