Artificial Intelligence-Derived Electrocardiographic Age Enhances Stroke Risk Stratification in Patients With Atrial Fibrillation With a CHA2DS2-VA Score of 1.
Chen-Shu Wu, Po-Huang Chen, Wen-Yu Lin, Wei-Ting Liu, Po Kai Chan, Hsuan Yi Wu, Chin-Sheng Lin, Chin Lin,
Division of Cardiology, Department of Medicine Tri-Service General Hospital, National Defense Medical University Taipei Taiwan. · Division of Hematology and Oncology, Department of Internal Medicine Tri-Service General Hospital, National Defense Medical University Taipei Taiwan.
Key points
From the paper's conclusion- Substituting chronological age with artificial intelligence-derived ECG-age in the CHA2DS2-VA score was associated with improved risk stratification in patients with atrial fibrillation with intermediate stroke risk. This refined risk stratification facilitates timely initiation of anticoagulation therapy, potentially reducing stroke and mortality. Future prospective studies are essential to integrate this artificial intelligence-enhanced strategy into clinical practice.
Abstract
BACKGROUND: To evaluate whether artificial intelligence-derived electrocardiographic-age enhances the predictive utility of the CHA2DS2-VA (congestive heart failure/left ventricular dysfunction, hypertension, age ≥75 years [doubled], diabetes, stroke/transient ischemic attack [doubled], vascular disease, age 65-74 years) score in patients with atrial fibrillation representing a borderline indication for anticoagulation with a score of 1. METHODS: From a multicenter atrial fibrillation and atrial flutter registry, we identified 832 anticoagulation-naïve patients with a CHA2DS2-VA score of 1 and at least one 12-lead ECG within 90 days of diagnosis. ECG-age was estimated using a previously validated deep learning (convolutional neural network) model. Chronological age was replaced with ECG-age (1 point for 65-74 years, 2 points for ≥75 years), leaving all other score components unchanged, to form the EA-CHA2DS2-VA score. Patients were grouped as EA-CHA2DS2-VA ≥2 (n=315) or <2 (n=517). RESULTS: Compared with patients with an EA-CHA2DS2-VA score <2, those with an EA-CHA2DS2-VA score ≥2 had a significantly higher risk of ischemic stroke or transient ischemic attack (hazard ratio [HR], 1.82 [95% CI, 1.06-3.13]; P=0.028). All-cause mortality was also significantly elevated in the EA-CHA2DS2-VA ≥2 group (HR, 2.22 [95% CI, 1.43-3.45]; P<0.001). Major bleeding did not differ significantly between groups (P=0.386). CONCLUSIONS: Substituting chronological age with artificial intelligence-derived ECG-age in the CHA2DS2-VA score was associated with improved risk stratification in patients with atrial fibrillation with intermediate stroke risk. This refined risk stratification facilitates timely initiation of anticoagulation therapy, potentially reducing stroke and mortality. Future prospective studies are essential to integrate this artificial intelligence-enhanced strategy into clinical practice. REGISTRATION: This study was registered on the Open Science Framework (URL: https://doi.org/10.17605/OSF.IO/39BND; unique identifier: 10.17605/OSF.IO/39BND).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Wearable device derived electrocardiographic age and its association with atrial fibrillationnpj Digital Medicine · 2026
- Using an Artificial Intelligence ECG-Derived Biological Age for Risk Stratification of Patients Undergoing Surgical Aortic Valve Replacement.The Annals of thoracic surgery · 2026
- AI-STRATA-AF study: an AI-ECG framework for dynamic thromboembolic risk assessment after atrial fibrillation ablationFrontiers in Cardiovascular Medicine · 2026
- Artificial intelligence-enabled analysis of handheld single-lead electrocardiograms to predict incident atrial fibrillation: an analysis of the VITAL-AF randomized trialnpj Digital Medicine · 2025
- Electrocardiographic aging based on artificial intelligence and the risk of heart failure and its subtypes: a multi-national studyEuropean Heart Journal · 2026
- The AI-ECG clock as a biomarker of cardiovascular ageing: molecular, genetic and clinical validation in three cohortsEuropean Heart Journal · 2026