Key points
From the paper's conclusion- Evidence remains insufficient to establish the superiority of any specific hs-cTn assay within the European Society of Cardiology 0-/1-hour algorithm. Although practical considerations may currently guide selection, continued validation of newer assays remains necessary.
Abstract
BACKGROUND: The European Society of Cardiology rapid rule-out and rule-in protocols using hs-cTns (high-sensitivity cardiac troponins) with blood collection at 0 and 1 hour (0/1 hour), 0 and 2 hours (0/2 hours), and 0 and 3 hours (0/3 hours) are accurate and widely used for evaluating non-ST-segment-elevation myocardial infarction. This network meta-analysis aimed to identify the best performing hs-cTn assay. METHODS: We conducted database searches up to January 15, 2026, a dual screening and eligibility assessment, independent data extraction and risk of bias assessment, a network meta-analysis of diagnostic accuracy, and assessment of the certainty of evidence. Only full-paired diagnostic accuracy studies conducted in the emergency department were included. RESULTS: Ten prospective studies (15 publications) comparing 10 assays using the 0-/1-hour algorithm (n=8769), 0-/2-hour algorithm (n=1881), and 0-/3-hour algorithm (n=1236) were included. Comparisons between newer and conventional assays largely stemmed from a single-source study. Across all assays, the European Society of Cardiology 0-/1-hour algorithm demonstrated high sensitivity (summary point estimate range: 97.8%-99.8%). Furthermore, it maintained high specificity (89.8%-98.1%), with no assay showing clear superiority. The summary sensitivity and specificity did not show significant differences across assays after adjusting for biases because of imperfect reference standards. Comparative data in the European Society of Cardiology 0-/2-hour and 0-/3-hour algorithms were limited. CONCLUSIONS: Evidence remains insufficient to establish the superiority of any specific hs-cTn assay within the European Society of Cardiology 0-/1-hour algorithm. Although practical considerations may currently guide selection, continued validation of newer assays remains necessary.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of a novel high-sensitivity cardiac troponin T assay in the ESC 0/1-hour algorithm for the early diagnosis of NSTEMIEuropean Heart Journal · 2026
- Validation of the ESC 0/3h-algorithm with a novel high-sensitivity cardiac troponin I assay in patients with suspected myocardial infarctionEuropean Heart Journal · 2026
- Can composite risk scores improve upon single sample rule-out performance in suspected acute coronary syndrome? A preplanned analysis of the MACROS 2 randomised controlled trialEuropean Heart Journal · 2026
- Diagnostic accuracy of high-sensitivity point-of-care troponin assays in emergency department for patients presenting with chest pain: a systematic review.European journal of emergency medicine : official journal of the European Society for Emergency Medicine · 2026
- Direct Comparison of the 0/1h- and 0/2h-Algorithms in Patients With Prior Coronary Artery Bypass Grafting.Journal of the American Heart Association · 2026
- Diagnostic performance between computed tomography angiography and high-sensitivity troponin for acute coronary syndrome in the emergency department: a systematic review and meta-analysis.Journal of thoracic disease · 2026